Pengaruh Orientasi Dan Volumetrik Glass Fiber Non Dental Terhadap Kekuatan Perlekatan Geser Fiber Reinforced Composites Untuk Splinting Periodontal

Abstract: Fiber Reinforced Composite (FRC) menggunakan E-glass fiber dental dalam bidang kedokteran gigi telah banyak diaplikasikan secara klinis, salah satunya dalam aplikasi splinting periodontal. Ketersediaan E-glass fiber dental di Indonesia masih terbatas dengan harga relatif mahal. Terdapat glass fiber non dental di Indonesia yang banyak digunakan bidang teknik, dengan harga terjangkau. Tujuan dari penelitian ini untuk mengetahui pengaruh orientasi dan volumetrik glass fiber non dental terhadap kekuatan perlekatan… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…FRC with glass fiber dental reinforcement has a smaller flexural strength value (120 MPa) than FRC which is reinforced with non-dental roving glass fiber (133 MPa) and woven roving (145 MPa) after soaking for 7 days (Khalil, 2015) 20 . Sumantri (2015) stated that FRC shear strength with glass fiber dental reinforcement was smaller (11.37 MPa) when compared with non-dental mats glass fiber (11.51 MPa) and non-dental woven roving glass fiber (12.58 MPa) in volumetric 2.8vol%. Fiber orientation has an influence on FRC shear strength, where fiber unidirectional orientation provides the highest strength and stiffness for composites 21 .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…FRC with glass fiber dental reinforcement has a smaller flexural strength value (120 MPa) than FRC which is reinforced with non-dental roving glass fiber (133 MPa) and woven roving (145 MPa) after soaking for 7 days (Khalil, 2015) 20 . Sumantri (2015) stated that FRC shear strength with glass fiber dental reinforcement was smaller (11.37 MPa) when compared with non-dental mats glass fiber (11.51 MPa) and non-dental woven roving glass fiber (12.58 MPa) in volumetric 2.8vol%. Fiber orientation has an influence on FRC shear strength, where fiber unidirectional orientation provides the highest strength and stiffness for composites 21 .…”
Section: Introductionmentioning
confidence: 99%
“…Sumantri (2015) stated that FRC shear strength with glass fiber dental reinforcement was smaller (11.37 MPa) when compared with non-dental mats glass fiber (11.51 MPa) and non-dental woven roving glass fiber (12.58 MPa) in volumetric 2.8vol%. Fiber orientation has an influence on FRC shear strength, where fiber unidirectional orientation provides the highest strength and stiffness for composites 21 . Sari (2015) states that the flexural strength value of FRC with 2.3vol% of volumetric fiberglass dental is lower (158.34 MPa) compared with FRC with non-dental mats glass fiber reinforcement (208.03 MPa), roving (165.28 MPa), and woven roving (204.65).…”
Section: Introductionmentioning