2015
DOI: 10.1016/j.ajem.2015.05.026
|View full text |Cite
|
Sign up to set email alerts
|

Pentax Airway Scope AWS-S200 video laryngoscope for child tracheal intubation in a manikin study with 3 airway scenarios

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 24 publications
0
3
0
Order By: Relevance
“…As shown by scientific studies, CC during direct laryngoscopy significantly prolongs intubation [8,22]. When applying various videolaryngoscopy methods, as in the case the ETView, thanks to obtaining an image of the end of the laryngoscope blade or of the endotracheal tube, the differences in the efficiency between intubation with and without CC are not as significant as with the MAC [33][34][35].…”
Section: Discussionmentioning
confidence: 97%
“…As shown by scientific studies, CC during direct laryngoscopy significantly prolongs intubation [8,22]. When applying various videolaryngoscopy methods, as in the case the ETView, thanks to obtaining an image of the end of the laryngoscope blade or of the endotracheal tube, the differences in the efficiency between intubation with and without CC are not as significant as with the MAC [33][34][35].…”
Section: Discussionmentioning
confidence: 97%
“…Three examples could well reflect the high variability in definition since time to intubation is described as (i) the time “from the passage of the tip of the laryngoscope past the patient’s teeth to the appearance of CO 2 on the capnograph trace” [20], (ii) the moment “from when the facemask was removed from the patient’s face to when end-tidal CO 2 of at least 20 mm Hg was measured on the end-tidal gas monitor” [21] or when (iii) “the time started to run when a participant took a laryngoscope into his/her hand and stopped when the appropriate position of the tube was confirmed by the fact that it was possible to ventilate with a bag valve mask and by the movements of the chest and the abdomen” (Fig. 3) [22].
Fig.
…”
Section: Set Of Parametersmentioning
confidence: 99%
“…11 As for Pentax AWS, a paediatric manikin based study reports shorter intubation time, higher success rate, and easier performance scores compared to Miller laryngoscopes. 12,13 There are no studies to our knowledge directly comparing Pentax AWS and Macintosh laryngoscope in paediatric patients. The purpose of this randomised non-inferiority study was to evaluate the efficacy of the Pentax AWS regarding intubation time, laryngeal view and ease of intubation in paediatric patients with normal airway, compared to Macintosh laryngoscope.…”
Section: Introductionmentioning
confidence: 99%