2020
DOI: 10.1016/j.talanta.2020.120926
|View full text |Cite
|
Sign up to set email alerts
|

Peptide-capped functionalized Ag/Au bimetal nanoclusters with enhanced red fluorescence for lysosome-targeted imaging of hypochlorite in living cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
22
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 45 publications
(27 citation statements)
references
References 51 publications
0
22
0
Order By: Relevance
“…Compared with QDs, noble MNCs not only have the advantages of QDs in biological imaging but also have the characteristics of small size, low toxicity, and good biocompatibility. Therefore, they become more attractive fluorescent probes in biological imaging [72,74,75]. Wu et al were the first group to use precious MNCs in near-infrared fluorescence imaging.…”
Section: Noble Mncs In Biotargeting and Bioimagingmentioning
confidence: 99%
“…Compared with QDs, noble MNCs not only have the advantages of QDs in biological imaging but also have the characteristics of small size, low toxicity, and good biocompatibility. Therefore, they become more attractive fluorescent probes in biological imaging [72,74,75]. Wu et al were the first group to use precious MNCs in near-infrared fluorescence imaging.…”
Section: Noble Mncs In Biotargeting and Bioimagingmentioning
confidence: 99%
“…Effort was then put in figuring out the origin of the peak at 460 nm (fluorescence or scatter peak from solvent, water [42,43] or Au NCs). As shown in Figure 2a, water and the aqueous solution of the free oligopeptide show exactly the same emission spectra (λ ex =376 nm), corresponding to the background peak of water [43] .…”
Section: Resultsmentioning
confidence: 99%
“…While the CCY moiety promoted the formation of Ag/Au alloy NCs, the RGRK-KRRQRRR sequence acted as a cell-penetrating probe through its lysosome-targeting sequence GRKKRRQRRR, and the γ-ECG fragment was able to interact with ROS, improving the stability of NCs in biological environments. Moreover, these fluorescent probes could also be useful for the detection of hypochlorite anion (ClO − ) in living cells, whose presence resulted in fluorescence quenching, redshifted emission maximum, and decreased lifetime [63]. By changing the domain sequence of the capping peptides, it was possible to modulate the binding specificity of metal NCs toward a precise biological target, or cellular organelle.…”
Section: Peptidesmentioning
confidence: 99%