2015
DOI: 10.1021/acs.analchem.5b00230
|View full text |Cite
|
Sign up to set email alerts
|

Peptide Code-on-a-Microplate for Protease Activity Analysis via MALDI-TOF Mass Spectrometric Quantitation

Abstract: A peptide-encoded microplate was proposed for MALDI-TOF mass spectrometric (MS) analysis of protease activity. The peptide codes were designed to contain a coding region and the substrate of protease for enzymatic cleavage, respectively, and an internal standard method was proposed for the MS quantitation of the cleavage products of these peptide codes. Upon the cleavage reaction in the presence of target proteases, the coding regions were released from the microplate, which were directly quantitated by using … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
37
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 33 publications
(37 citation statements)
references
References 36 publications
0
37
0
Order By: Relevance
“…). Their detection limits (3σ) were 3.8 pM and 2.2 nM, respectively, which were lower than those of 2.3 and 5.2 nM for the previous MALDI‐TOFMS analysis and comparable with some fluoresence, phosphorescence, or label‐free colormetric assays . All these results implied the effectiveness of the proposed method for multiple protease assay.…”
Section: Resultsmentioning
confidence: 54%
See 2 more Smart Citations
“…). Their detection limits (3σ) were 3.8 pM and 2.2 nM, respectively, which were lower than those of 2.3 and 5.2 nM for the previous MALDI‐TOFMS analysis and comparable with some fluoresence, phosphorescence, or label‐free colormetric assays . All these results implied the effectiveness of the proposed method for multiple protease assay.…”
Section: Resultsmentioning
confidence: 54%
“…However, preparation and purification of the probes is still time‐consuming. Our group proposed a peptide‐encoded microplate for matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS) analysis of trypsin and chymotrypsin, but internal standards were required for quantitation . Considering the fact that high‐resolution mass spectrometry (HRMS) can operate in the full‐scan operation mode with the special advantages of high throughput and can be used for accurate peptide quantitation without an internal standard, this work applied the peptide‐encoding technique for HRMS analysis of protease activities.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Some recently described arrangements employ nanoparticles (Feltrup and Singh, 2012;Khalilzadeh et al, 2016;Udukala et al, 2016;Wang et al, 2014;Zeng et al, 2015) or quantum dot bioconjugates (Lee and Kim, 2015;Li et al, 2014;Medintz et al, 2006) with immobilized fluorescently or luminescently labeled peptide substrates. Alternatively, cleavage products may be monitored by analysis of proteolytic products by mass spectrometric methods (Hu et al, 2015;Joshi et al, 2017;Lathia et al, 2011;Rumlová et al, 2003), analytical HPLC (Teruya et al, 2016), or electrochemical methods based on the difference in penetration of substrate and cleavage products through the membrane of a polyionselective sensor (Gemene and Meyerhoff, 2011;Han et al, 1996). To study the specificity of inhibitor binding and to extend the research to rational design of inhibitors, X-ray or NMR structures of proteases in complex with the inhibitor may be determined, as reported in numerous cases for the proteases of HIV-1 [reviewed in (Ghosh et al, 2016)], HCV (Yilmaz et al, 2016), and MERS .…”
Section: Assay and Methods For Screening And Evaluating Viral Maturatmentioning
confidence: 99%
“…Inrecent years,mass spectrometry (MS) has been proven to be apowerful method for enzyme activity assays owing to the advantages of high-throughput and label-free analyses. [1][2][3] However,i ts application is often limited by complicated sample pretreatments,including separation, purification, and desalting procedures. [4][5][6] To solve these problems,several gold chips with covalently assembled oligoethylene disulfide chains have been proposed for profiling the activities of kinases, [7] proteases, [8] and glycotransferases [9] and for identifying enzyme inhibitors, [10] and some aluminum oxide,g old, and ITOslides with immobilized glycan substrates have been developed for studying enzymatic reactions and protein binding.…”
mentioning
confidence: 99%