2015
DOI: 10.4244/eijy14m05_01
|View full text |Cite
|
Sign up to set email alerts
|

Percutaneous complete repair of failed mitral valve prosthesis: simultaneous closure of mitral paravalvular leaks and transcatheter mitral valve implantation – single-centre experience

Abstract: Complete transcatheter repair of a degenerated mitral bioprosthesis with PVR can be performed in the high-risk patient. Accurate measurement is necessary prior to intervention, with concern for embolisation among the larger valve sizes (>31 mm).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 31 publications
(20 citation statements)
references
References 26 publications
0
19
0
1
Order By: Relevance
“…In addition to TA and TS access, a direct transatrial access using a sheath placed directly into the left atrium via a right anterior thoracotomy was also used in two patients . The “TA + TS” access was utilized for the Melody valve . Transcatheter valves were used in all patients and included the SAPIEN XT ( n = 120, Edwards Lifesciences, Irvine, CA), SAPIEN ( n = 47, Edwards Lifesciences), SAPIEN 3 ( n = 26, Edwards Lifesciences), Melody ( n = 18, Medtronic, Minneapolis, MN), Tiara ( n = 4, Neovasc Inc, Richmond, Canada), Lotus ( n = 3, Boston Scientific, Natick, MA), Tendyne ( n = 1, Abbott, Abbott Park, IL), and Direct Flow Medical transcatheter valve system (DFM) ( n = 9, Direct Flow Medical Inc, Santa Rosa, CA).…”
Section: Resultsmentioning
confidence: 99%
“…In addition to TA and TS access, a direct transatrial access using a sheath placed directly into the left atrium via a right anterior thoracotomy was also used in two patients . The “TA + TS” access was utilized for the Melody valve . Transcatheter valves were used in all patients and included the SAPIEN XT ( n = 120, Edwards Lifesciences, Irvine, CA), SAPIEN ( n = 47, Edwards Lifesciences), SAPIEN 3 ( n = 26, Edwards Lifesciences), Melody ( n = 18, Medtronic, Minneapolis, MN), Tiara ( n = 4, Neovasc Inc, Richmond, Canada), Lotus ( n = 3, Boston Scientific, Natick, MA), Tendyne ( n = 1, Abbott, Abbott Park, IL), and Direct Flow Medical transcatheter valve system (DFM) ( n = 9, Direct Flow Medical Inc, Santa Rosa, CA).…”
Section: Resultsmentioning
confidence: 99%
“…Majority of the cases have been performed using the SAPIEN/SAPIEN XT balloon expandable valve (Edwards Lifesciences, Irvine, CA) and few with the self-expanding Melody valve (Medtronic, Minneapolis, MN) [11,12]. Further expansion of this indication to treat failed mitral valve repairs with complete or incomplete rings, that is valve-in-ring (VIR), has also been successful [13].…”
Section: Introductionmentioning
confidence: 99%
“…guidance has been utilized for directed transcatheter access, as well as for procedural interventions in the treatment of both valvular and paravalvular regurgitation(28)(29)(30)(31).TRANSCATHETER THERAPIES FOR AR NATIVE VALVES. Currently, there are no approved THVs for the treatment of native valve AR in the United States.…”
mentioning
confidence: 99%