2014
DOI: 10.4244/eijv10i5a107
|View full text |Cite
|
Sign up to set email alerts
|

Percutaneous mitral valve repair with the MitraClip: early results from the MitraClip Asia-Pacific Registry (MARS)

Abstract: Results from the Asia-Pacific region show that the MitraClip procedure is effective in reducing mitral regurgitation and has favourable short-term safety outcomes.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
17
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 43 publications
(21 citation statements)
references
References 14 publications
3
17
0
1
Order By: Relevance
“…As in previous studies, clip embolization was not observed in the present registry. In fact, only a single case of clip embolization has been reported worldwide, so far [1,[3][4][5]8,[16][17][18][19][20][21][22][23][24][25][26][27][28][29] (Table V). Partial clip detachment from one leaflet was rarely observed (2% in the present analysis) and occurred spontaneously or during advancement of a second clip for residual MR.…”
Section: Discussionmentioning
confidence: 99%
“…As in previous studies, clip embolization was not observed in the present registry. In fact, only a single case of clip embolization has been reported worldwide, so far [1,[3][4][5]8,[16][17][18][19][20][21][22][23][24][25][26][27][28][29] (Table V). Partial clip detachment from one leaflet was rarely observed (2% in the present analysis) and occurred spontaneously or during advancement of a second clip for residual MR.…”
Section: Discussionmentioning
confidence: 99%
“…The M itraClip in the A sia‐Pacific R egi s try (MARS) is a multicenter retrospective registry, involving eight sites in five Asia‐Pacific countries (Australia, China, Indonesia, Malaysia and Singapore), that collects data on patients with significant MR who have undergone the MitraClip procedure. The details of this registry, as well as inclusion and exclusion criteria, have previously been described . In summary, the clinical decision for the MitraClip was made only after assessment by a multidisciplinary team involving interventional cardiologists, echocardiologists, heart failure specialists and cardiac surgeons.…”
Section: Methodsmentioning
confidence: 99%
“…Indeed, there were no cases of conversion to open chest surgery in this study and the safety of the device has already been demonstrated in other large studies and registries. 3,5,8-21, 25 Therefore, a hybrid operating room may not be necessary for this procedure.…”
Section: Study Limitationsmentioning