1997
DOI: 10.1016/s0363-5023(97)80159-1
|View full text |Cite
|
Sign up to set email alerts
|

Percutaneous pinning of distal radius fractures: A biomechanical study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
65
0
2

Year Published

2002
2002
2016
2016

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 92 publications
(68 citation statements)
references
References 7 publications
1
65
0
2
Order By: Relevance
“…[10,11,12,13] However, cross-pin fixation is advocated the most effective method for excellent stability of all major fragments. [14] There is scarce evidence as to the most appropriate number and placement of K-wires and supporting techniques.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…[10,11,12,13] However, cross-pin fixation is advocated the most effective method for excellent stability of all major fragments. [14] There is scarce evidence as to the most appropriate number and placement of K-wires and supporting techniques.…”
Section: Discussionmentioning
confidence: 99%
“…Hence, the authors described the differences in rigidity according to pin size, and advocated that at least 1.6 mm diameter K-wires were needed for stable cross-pin fixation. [14] In both groups, similar cross-pin fixation (with 1.8-2.0 mm K-wire) was applied. Biomechanical study could not be carried out for this case series because our study patients had both intra-articular and extra-articular fractures of the distal radius.…”
Section: Günay Et Al Two Different Treatment Technique In Distal Radmentioning
confidence: 99%
“…Use of threaded pins provides a good support than smooth pins in osteoporotic bones and prevents pin loosening. Percutaneous pinning is a minimally invasive procedure that offers good stability and early range of motion and least chances of stiffness when compared to open surgical plating 20 .…”
Section: Discussionmentioning
confidence: 99%
“…Several biomechanical studies had been done to compare different wire configurations in fixation of proximal humeral fractures. They found that a parallel configuration is better than a convergent configuration in both rotational and bending stresses and that a divergent configuration is better than a parallel configuration in rotational stresses [8,14,19]. The palm tree technique allows for insertion of the wires in a divergent manner that insures stable fixation.…”
Section: Discussionmentioning
confidence: 99%