2019
DOI: 10.4172/interventional-cardiology.1000622
|View full text |Cite
|
Sign up to set email alerts
|

Percutaneous retrieval of complicated intravascular devices

Abstract: Background: Cardiac catheterization procedures are sometimes associated with unanticipated serious complications related to intravascular devices (IVD) which include embolization, displacement, knotting, entrapment etc. Percutaneous management is difficult and may even warrant surgical extraction. We evaluated clinical profile, causes, management and outcomes of percutaneous retrieval of such complicated IVD Methods and Findings: In this retrospective, single-center study, medical and procedural records of all… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(12 citation statements)
references
References 19 publications
1
11
0
Order By: Relevance
“…There are various retrieval devices available for endovascular IFBR: snares, Dormia baskets, biopsy forceps, tip-deflecting wires, pincher devices, oversized sheaths or balloon catheters. 1 However, like in our series, the large majority of endovascular IFBR uses a snare. In one series, only 8.7% of displaced devices were retrieved with a device other than a snare.…”
Section: Tablesupporting
confidence: 50%
See 3 more Smart Citations
“…There are various retrieval devices available for endovascular IFBR: snares, Dormia baskets, biopsy forceps, tip-deflecting wires, pincher devices, oversized sheaths or balloon catheters. 1 However, like in our series, the large majority of endovascular IFBR uses a snare. In one series, only 8.7% of displaced devices were retrieved with a device other than a snare.…”
Section: Tablesupporting
confidence: 50%
“…Those located within the cardio-pulmonary system pose the most significant risk. 1,7 Infectious complications are high in broken catheter fragments; it arises from bacterial contamination. Misplaced coils cause local thrombogenicity, ischemia, and perforation.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…BM was dissolved in castor oil in a screw-capped glass container and mixed with other components at the concentration of (2.5 mg / 0.3 ml) and heated in a water bath at (50 -60°C) to facilitate homogenization. The components were mixed by vortex mixing for 5 min to obtain a clear, uniform mixture and again cooled to room temperature followed by equilibrating the mixture on a sonication at a room temperature for 10 min, after that the formulations were kept under visual observation for at least 48h (at room temperature) and examined for any signs of turbidity or phase separation prior to droplet size distribution studies (13)(14)(15) .…”
Section: Preparation Of Bromocriptinemesylate Liquid Self-nanoemulsifmentioning
confidence: 99%