2014
DOI: 10.1021/es503490z
|View full text |Cite
|
Sign up to set email alerts
|

Perfluoroalkylated Substances in the Global Tropical and Subtropical Surface Oceans

Abstract: In this study, perfluoroalkylated substances (PFASs) were analyzed in 92 surface seawater samples taken during the Malaspina 2010 expedition which covered all the tropical and subtropical Atlantic, Pacific and Indian oceans. Nine ionic PFASs including C6−C10 perfluoroalkyl carboxylic acids (PFCAs), C4 and C6−C8 perfluoroalkyl sulfonic acids (PFSAs) and two neutral precursors perfluoroalkyl sulfonamides (PFASAs), were identified and quantified. The Atlantic Ocean presented the broader range in concentrations of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

14
96
2
2

Year Published

2016
2016
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 111 publications
(114 citation statements)
references
References 73 publications
14
96
2
2
Order By: Relevance
“…A range of 0.03-89 ng/L PFOS was detected in river water of eastern China [4]. In Atlantic, Indian and Pacific oceans, PFBS, PFHxS and PFOS occurred in a range of 20.0-45.4 pg/L, 6.65-32.4 pg/L and 88. pg/L respectively [5]. PFOS was also found in Tibetan Mountain with a concentration range of 25.0-64.2 pg/L in surface snow and 61.4-346 pg/L in snow core [6].…”
Section: Introductionmentioning
confidence: 91%
See 3 more Smart Citations
“…A range of 0.03-89 ng/L PFOS was detected in river water of eastern China [4]. In Atlantic, Indian and Pacific oceans, PFBS, PFHxS and PFOS occurred in a range of 20.0-45.4 pg/L, 6.65-32.4 pg/L and 88. pg/L respectively [5]. PFOS was also found in Tibetan Mountain with a concentration range of 25.0-64.2 pg/L in surface snow and 61.4-346 pg/L in snow core [6].…”
Section: Introductionmentioning
confidence: 91%
“…The full scan mass range was set at 200-700 m/z with a resolution of 120,000 (FWHM at 200 m/z). Automatic gain control (AGC) target was assigned a value of 1.0e 5 (maximum number of ions filling C-Trap) with a maximum injection time of 100 ms. For dd-MS 2 scan, precursor ion selection range was limited at 250-650 m/z with a mass tolerance of 0.5 m/z and quadrupole isolated the precursor ions with an isolation window of 1 m/z. Only those precursor ions that had a signal threshold >1.0e 4 counts were permissible for MS 2 fragmentation activation with 40% collision energy.…”
Section: Liquid Chromatography-orbitrap Tribrid Hrmsmentioning
confidence: 99%
See 2 more Smart Citations
“…. Surface PFOS measurements are fromAhrens et al [2009aAhrens et al [ , 2009bAhrens et al [ , 2010b;Benskin et al [2012],Gonzalez-Gaya et al [2014], andZhao et al [2012]. Surface PFOS measurements are fromAhrens et al [2009aAhrens et al [ , 2009bAhrens et al [ , 2010b;Benskin et al [2012],Gonzalez-Gaya et al [2014], andZhao et al [2012].…”
mentioning
confidence: 99%