2021
DOI: 10.11591/ijpeds.v12.i1.pp532-541
|View full text |Cite
|
Sign up to set email alerts
|

Performance analysis of 30 MW wind power plant in an operation mode in Nouakchott, Mauritania

Abstract: In this paper, the performance analysis of a 30 MW wind power plant is performed. The farm consists of fifteen (T1-T15) G9 7/2000/GAMESA 2 MW grid-connected turbines. The farm is in operation mode installed 28 km south of Nouakchott city in Mauritania. The analyzed data are monitored from July 1st, 2015 (the first operation day of the power plant) to December 31st, 2019. The parameters of performance evaluation are power generation, capacity factor, machine availability, grid availability, and system availabil… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
5

Relationship

1
9

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 12 publications
0
10
0
Order By: Relevance
“…Cellular networks, internet broadcastings, Wi-Fi gadgets, wireless local area network (WLAN), and other potential sources of electromagnetic radiation are therefore considered. Due to utilizing the applications, most people are exposed to an extended dose of radiation for a considerable period [27]. As previously stated, the results were held in Ramadi city in arbitrarily, somehow, uniformly dispersed picked spots.…”
Section: Resultsmentioning
confidence: 78%
“…Cellular networks, internet broadcastings, Wi-Fi gadgets, wireless local area network (WLAN), and other potential sources of electromagnetic radiation are therefore considered. Due to utilizing the applications, most people are exposed to an extended dose of radiation for a considerable period [27]. As previously stated, the results were held in Ramadi city in arbitrarily, somehow, uniformly dispersed picked spots.…”
Section: Resultsmentioning
confidence: 78%
“…Taking into account the non-linear large-scale DG model and ignoring the changes in direct current (DC) bus voltage and switching harmonics, we assume that there are inductive distribution lines and that the DGs can talk to each other without interruption. In the given circumstances, it is possible to identify the (P/active and Q/reactive ) power provided by the DG situated in i th position within the distribution network [29].…”
Section: Cooperative Control Objectivementioning
confidence: 99%
“…Therefore, the reactive and real powers that flow through the power line are computed. Also, The losses can be assessed depending on comparing the power flow in sending and receiving terminals of the system [2]- [5]. The fault in the power network is a problematic failure that causes abnormal conditions leading to technical failure in the operating equipment.…”
Section: Introductionmentioning
confidence: 99%