Performance analysis of a solar air heater modified with zig-zag shaped copper tubes using energy-exergy methodology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 49 publications
0
7
0
Order By: Relevance
“…Energies 2021, 14, 4838 6 of 19 Energy equilibrium can be expressed by Equation (11), which states that the input energy is equal to the output energy [32].…”
Section: Energy Efficiency and Energy Lossmentioning
confidence: 99%
See 1 more Smart Citation
“…Energies 2021, 14, 4838 6 of 19 Energy equilibrium can be expressed by Equation (11), which states that the input energy is equal to the output energy [32].…”
Section: Energy Efficiency and Energy Lossmentioning
confidence: 99%
“…The use of the improvement potential can also be helpful in the evaluation of economic activities [37]. The exergy improvement potential and the exergetic sustainability index can be expressed by Equations ( 30) and (31), respectively [32].…”
Section: Ex Loss =mentioning
confidence: 99%
“…As soon as the flow rate increases, the outlet temperature of the air decreases, resulting in a decrease in exergy efficiency after the optimum point. For the results presented in Figure 29, studies [144][145][146] are numerical investigations, while [147] is an experimental study that showed a different trend. The numerical investigations showed that exergy efficiency starts to decrease at lower flow rates, while experimental investigations demonstrated an inverse trend, as shown in Figure 29.…”
Section: Exergy Analysismentioning
confidence: 99%
“…Sahu et al (2021) revealed that the arc-shape rib roughened SAC has a maximum thermal efficiency of 71.6% for apex-upstream and 55.8% for apex-downstream than the smooth pass solar air collector (SPSAC) for a mass flow rate ranging from 0.010 to 0.047 kg s −1 . Kumar et al (2021) analyzed the thermohydraulic performance of the SAC with zig-zag-shaped copper tubes and revealed that the maximum value of energy and exergy efficiency as 62.8% and 58.48% was obtained at an airflow rate of 0.05 kg/s. Tabish et al (2021) analytically evaluated the performance of the protrusion rib-roughened SAC and found that the net effective efficiency of 70.92% was achieved at a rib pitch ratio of 10 and rig height ratio of 0.0289.…”
Section: Introductionmentioning