2014 Power and Energy Systems: Towards Sustainable Energy 2014
DOI: 10.1109/pestse.2014.6805315
|View full text |Cite
|
Sign up to set email alerts
|

Performance analysis of four-switch three-phase inverter-fed induction motor drive

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 4 publications
0
3
0
Order By: Relevance
“…The effectiveness of the Z-Source VFDs is proven by no overshoot, no undershoot and zero steady-state error of the speed response. It is also seen in Figure 6 and Figure 7 that the speed response and the harmonic distortion of the reduced switch three phase Z-source VFD based IM drive It is found that the performance of the reduced switch three phase Z-source VFD based drive is much close to that of the traditional six switches three phase VFD [14]. The analysis and simulation results show that this VFD can dramatically reduce the complexity of the control algorithms and cost.…”
Section: Resultsmentioning
confidence: 69%
“…The effectiveness of the Z-Source VFDs is proven by no overshoot, no undershoot and zero steady-state error of the speed response. It is also seen in Figure 6 and Figure 7 that the speed response and the harmonic distortion of the reduced switch three phase Z-source VFD based IM drive It is found that the performance of the reduced switch three phase Z-source VFD based drive is much close to that of the traditional six switches three phase VFD [14]. The analysis and simulation results show that this VFD can dramatically reduce the complexity of the control algorithms and cost.…”
Section: Resultsmentioning
confidence: 69%
“…Literatures [14][15][16][17] concentrated on different control strategies for FSTP induction motors (IMs). In [18][19][20][21], the researchers focused on the applications of FSTP topologies in brushless DC (BLDC) [18,21] and DC motors [19,20], however, the machines mentioned above are not usually applied in wind energy conversion systems.…”
Section: Introductionmentioning
confidence: 99%
“…Sinusoidal pulse with modulation technique is very famous technique for voltage source inverter because it is simple in implementation with low output harmonic contents [1,[9][10]. Analysis of six switches based three phase inverter and four switches based three phase inverter with PWM and Sinusoidal PWM comparison shows unbalanced phase currents, speed variations and higher THD of four switch three phase inverter fed induction motor discussed in [14]. Speed control is achieved in inverter driven induction motor by means of variable frequency.…”
Section: Introductionmentioning
confidence: 99%