Proceedings Eighth Annual Applied Power Electronics Conference and Exposition,
DOI: 10.1109/apec.1993.290714
|View full text |Cite
|
Sign up to set email alerts
|

Performance analysis of parallel-processing UPS systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…is the rate of change of the frequency deviation in rad/sec 2 and is the rate of change of the voltage deviation in V/sec. From Fig.…”
Section: B Drooping Coefficients Selectionmentioning
confidence: 99%
See 1 more Smart Citation
“…is the rate of change of the frequency deviation in rad/sec 2 and is the rate of change of the voltage deviation in V/sec. From Fig.…”
Section: B Drooping Coefficients Selectionmentioning
confidence: 99%
“…The classical topology of line interactive UPS systems [1], [2] is simpler, cheaper, more efficient and more reliable than the on-line double conversion UPS. This topology, however, does not provide voltage regulation to the load.…”
Section: Introductionmentioning
confidence: 99%
“…According to (4) and (5), the small-signal model of the dc-link voltage control is presented in Fig. 7.…”
Section: Limitation Of the Traditional Model To Design The Contrmentioning
confidence: 99%
“…Thereby, active filter topologies have been used to compensate neutral harmonic currents (Quinn et al, 1992;Quinn et al, 1993;Thomas el al., 1996). Uninterruptible power supply (UPS) systems have enabled the improvement of power source quality, providing clean and uninterruptible power to critical loads such as industrial process controls, computers, medical equipment, data communication systems, and protection against power supply disturbances or interruptions (Oliveira da Silva et al, 2001;Kamran et al, 1995;Jeon et al, 1997, Cheung et al, 1996Lin et al, 1993). In (Lin et al, 1993) a threephase parallel processing UPS has been presented with harmonic and reactive power compensation, but the output voltages and the input currents cannot be controlled simultaneously.…”
Section: Introductionmentioning
confidence: 99%
“…Uninterruptible power supply (UPS) systems have enabled the improvement of power source quality, providing clean and uninterruptible power to critical loads such as industrial process controls, computers, medical equipment, data communication systems, and protection against power supply disturbances or interruptions (Oliveira da Silva et al, 2001;Kamran et al, 1995;Jeon et al, 1997, Cheung et al, 1996Lin et al, 1993). In (Lin et al, 1993) a threephase parallel processing UPS has been presented with harmonic and reactive power compensation, but the output voltages and the input currents cannot be controlled simultaneously. Three-phase UPS systems with seriesparallel active power-line conditioning have been proposed using different control strategies (Oliveira da Silva et al, 2001;Kamran et al, 1995).…”
Section: Introductionmentioning
confidence: 99%