“…The cycle efficiency increases with the design expansion pressure ratio as the condensation temperature in the HT cycle TC,HT decreases, but the size of the swash plate-type expander also increases. In a previous study [11], decreasing TC,HT from 139 to 120 °C and then 105 °C caused the HT cycle power to increase by about 21% and 38%, respectively, although the LT cycle power was constant. However, the volume of the HT expander had to be increased by approximately 67% and 165%, respectively, to achieve this, which is a disadvantage.…”