Performance and applications of the Toulouse 3 million volt electron microscope

Abstract: his paper describes the electron microscope and gives details of its performance at an operating voltage of 3 MV.Some initial results are reported concerning : penetrating power; resolving power; studies of radiation damage, and other interactions between electrons and crystalline materials. Several observations are also described concerning biological materials (bacteria, frog skeletal muscle, filaments from mushroom spores . . .).Because at high voltage, radiation damage is considerably reduced, the results … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

1973
1973
1994
1994

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 30 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…Dark-field images with good contrast even at 3 MV have been obtained of muscle (Fig. 5) by Dupouy (1973) and of ferritin by Massover (1974).…”
Section: A P P L I C a T I O N S I N B I O L O G Ymentioning
confidence: 95%
See 2 more Smart Citations
“…Dark-field images with good contrast even at 3 MV have been obtained of muscle (Fig. 5) by Dupouy (1973) and of ferritin by Massover (1974).…”
Section: A P P L I C a T I O N S I N B I O L O G Ymentioning
confidence: 95%
“…Accounts of other applications of the high voltage microscope in metallurgy and metal physics are given in the two sources already quoted (J. Microscopy, 97, parts 1 and 2, 1973;Swann et al, 1974), and also in Thomas (1972). The most important concern (a) dynamic studies of the movement of grain boundaries and dislocations, and the formation of cavities and precipitates, when a specimen is subjected to heating and/or straining in situ (Fig.…”
Section: E T a L L U R G I C A L A P P L I C A T I O N Smentioning
confidence: 99%
See 1 more Smart Citation
“…The maximum operating voltage of most HVEMs is I or 1.2 MV, but microscopes operating up to 3 MV have been constructed in Toulouse and in Osaka, and a l0 MV microscope is under construction in Japan. Full instrumental details of HVEMs are given in reviews by Cosslett (1969Cosslett ( , 1971, Dupouy (1968Dupouy ( , 1973Dupouy ( , 1974 and .…”
Section: High Voltage Electron Microscopymentioning
confidence: 99%
“…A regular geometric arrangement of these granules was very rare. Dupouy's (1968; dark-field imaging technique has also been used to obtain remarkable pictures of bacterial flagella (Dupouy et al, 1969) and of bacterial cell walls (Dupouy, 1973). The cell walls were lightly stained with phosphotungstic acid, and a regular periodic structure was visible ( Fig.…”
Section: High Resolution Micrographs Of Thin Specimensmentioning
confidence: 99%