2012
DOI: 10.1002/rcm.6308
|View full text |Cite
|
Sign up to set email alerts
|

Performance and geometry optimization of the ceramic‐based rectilinear ion traps

Abstract: The ceramic-based rectilinear ion trap (cRIT) can be a qualified linear ion trap mass analyzer with high ion storage capability, excellent mass resolution, and high tandem mass analysis efficiency. It can be easily manufactured and operated, and has great potential in ion trap mass spectrometry.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
35
0

Year Published

2013
2013
2016
2016

Publication Types

Select...
10

Relationship

5
5

Authors

Journals

citations
Cited by 28 publications
(36 citation statements)
references
References 49 publications
1
35
0
Order By: Relevance
“…163 Chaudhary and coworkers constructed a miniature cylindrical ion trap by punching donut shapes from a sheet of low-temperature co-fired ceramic, laminating the sheets, firing the structure, plating the surface with Ni for adhesion and Au for conductivity via sputtering or evaporation, and finally photolithographically etching the appropriate electrode pattern. Other traps, including those with planar resistive electrodes, 164 a halo ion trap, 120 a rectilinear ion trap, 165 and, most recently, a linear ion trap array with six mass analyzers 144 have been built using metal-coated ceramic materials.…”
Section: Mems and Other Alternative Fabrication Methodsmentioning
confidence: 99%
“…163 Chaudhary and coworkers constructed a miniature cylindrical ion trap by punching donut shapes from a sheet of low-temperature co-fired ceramic, laminating the sheets, firing the structure, plating the surface with Ni for adhesion and Au for conductivity via sputtering or evaporation, and finally photolithographically etching the appropriate electrode pattern. Other traps, including those with planar resistive electrodes, 164 a halo ion trap, 120 a rectilinear ion trap, 165 and, most recently, a linear ion trap array with six mass analyzers 144 have been built using metal-coated ceramic materials.…”
Section: Mems and Other Alternative Fabrication Methodsmentioning
confidence: 99%
“…The x and y electrodes were machined via the newest ceramic gold-plating technology. [34][35][36][37] Each electrode was 40 and 5 mm in length and width, respectively. A side electrode and a central electrode with a slit (32 mm × 0.7 mm) were located at the center of the x and y electrodes and used as adjustable electrodes.…”
Section: Lit Mass Analyzermentioning
confidence: 99%
“…As previously reported, 38,41,42 tandem mass spectrometry experiments involve several stages including ion injection, ion cooling, ion isolation, collision-induced dissociation, and mass analysis. Ion excitation in both x-and y-directions was performed by turning on the CD4066 switch with a DC voltage of 9 V in the stage of collision-induced dissociation.…”
Section: ■ Results and Discussionmentioning