2016
DOI: 10.11591/ijpeds.v7.i1.pp66-74
|View full text |Cite
|
Sign up to set email alerts
|

Performance and High Robustness DPC for PWM Rectifier under Unstable Direct Voltage Bus

Abstract: This paper proposes a strategy de controlling a static AC/DC converter based on direct power control (DPC). The instantaneous active and reactive power   is controlled in such a way to ensure the PWM rectifier with a sinusoidal current absorption. This control has proven effective in terms of reduction of total harmonic distortion (THD) of current absorbed. Offers a good control of active and reactive power with an operation   at unitary power factor. The test of robustness carried out and the results have pro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2017
2017
2018
2018

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…The figure .2 shows the configuration of the direct power control without voltage sensor for a three phase inverter. The estimated values of (p s ) and (q s ) in terms of the three phase line currents and voltages can be derived as: [14] s S S S P jQ …”
Section: Direct Power Controlmentioning
confidence: 99%
“…The figure .2 shows the configuration of the direct power control without voltage sensor for a three phase inverter. The estimated values of (p s ) and (q s ) in terms of the three phase line currents and voltages can be derived as: [14] s S S S P jQ …”
Section: Direct Power Controlmentioning
confidence: 99%
“…Switching Table Vdc Comparing the instantaneous active power (P) at a reference power (P ref ), this latter is obtained by the DC voltage control block at the capacitor terminals, where we use a PI controller (Proportional, integrator) tocontrol the error between the sensed voltage (continuous) and reference [18], [20], [21]. Whilst to achieve a unity power factor, reactive power reference is directly imposed zero (Q ref =0).…”
Section: Power and Voltage Calculationmentioning
confidence: 99%
“…The main idea of the direct power control (DPC) originally proposed by Ohnishi (1991) and further developed by Noguchi et al in 1998, is similar to the direct torque control (DTC) of induction machines. Instead of flux and torque, the active power ( p ) and reactive power ( q ) are selected as two instantaneous magnitudes to control (figure 5), [10].…”
Section: Direct Power Controlmentioning
confidence: 99%
“…The estimated values of ( s p ) and ( s q ) in terms of the switching states of the converter, the three phase line currents, the dc-bus voltage, and the inductance of the reactors can be derived as, [4,10].…”
Section: Direct Power Controlmentioning
confidence: 99%
See 1 more Smart Citation