Performance Assessment of a Building-Integrated Photovoltaic Thermal System in a Mediterranean Climate—An Experimental Analysis Approach

Abstract: The experimental investigation of building-integrated photovoltaic thermal (BIPVT) solar systems is essential to characterise the operation of these elements under real conditions of use according to the climate and building type they pertain. BIPVT systems can increase and ensure energy performance and readiness without jeopardising the occupant comfort if correctly operated. The present work presents a case study’s experimental analysis composed of a BIPVT system for heat recovery located in a controlled tes… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 32 publications
0
3
0
Order By: Relevance
“…Bot et al [30] presented an experimental study of a BIPVT system for heat recovery in a test room. The focus was on presenting the measured values that represented the main boundary (room and weather characteristics) conditions and the thermal behavior and performance of the BIPVT system.…”
Section: Literature Reviewmentioning
confidence: 99%
“…Bot et al [30] presented an experimental study of a BIPVT system for heat recovery in a test room. The focus was on presenting the measured values that represented the main boundary (room and weather characteristics) conditions and the thermal behavior and performance of the BIPVT system.…”
Section: Literature Reviewmentioning
confidence: 99%
“…The experimental analysis to study the characteristics of real conditions in the mild Mediterranean climate of a BIPVT installed in a façade was done by Bot et al [131]. The weather parameters ambient temperatures during one year, global radiation, diffuse radiation, indoor room temperatures, and normal direct radiation components were registered.…”
Section: Overview Of Bipv Systemsmentioning
confidence: 99%
“…The design and operation of net zero energy buildings can be achieved by incorporating BIPVT systems. An experimental analysis of the properties of BIPVT installed in the facade under real conditions in the Mediterranean climate was performed by Bot et al [26]. Lee et al experimentally investigated the operational performance of color BIPV modules based on comparative analysis under outdoor experimental conditions [27].…”
Section: Introductionmentioning
confidence: 99%