Performance Assessment of a Commercial Continuous-Wave Near-Infrared Spectroscopy Tissue Oximeter for Suitability for Use in an International, Multi-Center Clinical Trial

Abstract: Despite the wide range of clinical and research applications, the reliability of the absolute oxygenation measurements of continuous wave near-infrared spectroscopy sensors is often questioned, partially due to issues of standardization. In this study, we have compared the performances of 13 units of a continuous wave near-infrared spectroscopy device (PortaMon, Artinis Medical Systems, NL) to test their suitability for being used in the HEMOCOVID-19 clinical trial in 10 medical centers around the world. Detai… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
4

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
2
1

Relationship

2
5

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 44 publications
0
8
4
Order By: Relevance
“…Nevertheless, it is important to notice that single measurements variability was on average approximately 0.7% (%CV). This observation was slightly lower compared to previous studies [24], and again emphasizes the accuracy of the sensor regarding the variability of the hemodynamics of the human tissue. In conclusion, it was found that intra-sensor variability was slightly higher in phantoms compared with in vivo measurements, and reproducibility on different days is as expected higher in vivo measurements.…”
Section: Test B -Intra-variability Due To Device Repositioning Over T...contrasting
confidence: 74%
See 3 more Smart Citations
“…Nevertheless, it is important to notice that single measurements variability was on average approximately 0.7% (%CV). This observation was slightly lower compared to previous studies [24], and again emphasizes the accuracy of the sensor regarding the variability of the hemodynamics of the human tissue. In conclusion, it was found that intra-sensor variability was slightly higher in phantoms compared with in vivo measurements, and reproducibility on different days is as expected higher in vivo measurements.…”
Section: Test B -Intra-variability Due To Device Repositioning Over T...contrasting
confidence: 74%
“…These results suggest as well that the Train.Red Fyer sensor can be stable for a long period of time, under different conditions, not variating significantly when conducted by different operators. We did not observe the presence of a period of warmup as Cortese et al [24] experienced. The CV obtained in this study is comparable to what was reported in the literature [24] even if the recording period is different, i.e.,3hrs in our study VS 7hrs in the existing study; although they excluded the first 1hr for the warm-up period.…”
Section: Test a -Stability During Duration Measurementscontrasting
confidence: 63%
See 2 more Smart Citations
“…NIRS provides non-invasive and non-ionizing technology that has been used to measure variations in oxygenated and deoxygenated hemoglobin concentrations in various human tissues [32][33][34]. It has been shown that NIRS provides consistent readings with other measurement modalities in various applications, including cerebral blood flow [35] and skeletal muscle contractions [36].…”
Section: Nirsmentioning
confidence: 99%