2022
DOI: 10.1016/j.ijheatmasstransfer.2021.122497
|View full text |Cite
|
Sign up to set email alerts
|

Performance characteristics of a divergent vortex tube

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(10 citation statements)
references
References 13 publications
0
10
0
Order By: Relevance
“…Based on Table 1, obtained from the experimental results of air from the compressor engine, with power capacity of 7.5 Kw, maximum pressure of 9.75 Bar, and maximum inlet temperature of 46 o C, the CFD process used several input parameters [22]. The main parameter is the variation of inlet pressure between 1-5 Bars [23]. Pressure variations are carried out to determine the thermodynamic characteristics that occur in the VT [24].…”
Section: Methods 21 Cfd 3d Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…Based on Table 1, obtained from the experimental results of air from the compressor engine, with power capacity of 7.5 Kw, maximum pressure of 9.75 Bar, and maximum inlet temperature of 46 o C, the CFD process used several input parameters [22]. The main parameter is the variation of inlet pressure between 1-5 Bars [23]. Pressure variations are carried out to determine the thermodynamic characteristics that occur in the VT [24].…”
Section: Methods 21 Cfd 3d Modelmentioning
confidence: 99%
“…Experimental data in the form of velocity, temperature, and pressure. The instrument used during the experiment was to collect pressure data using a pressure gauge, collect temperature data using a thermal image camera and thermostat (Thermocouple Type-K) [23], and collect air velocity data using a digital anemometer with input parameters in Table 1.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The U-tube works as a heat exchanger between the ground and the natural gas. The energy balance is shown in Equation ( 4) utilizing a specific heat definition [48]:…”
Section: Geothermal Heat Inputmentioning
confidence: 99%
“…Bazgir et al 13 explained on temperature detachment was explained using different turbulence models of a straight tube with the counter flow of RHVT; RNG k–ϵ model with respective to FMV; The results were explained 20 divergence is the optimal and critical length as 166 mm temperature elimination with increased with the number of nozzles. Cartlidge et al 14 investigated with divergent vortex tube with an inlet pressure of 3–7 bar, with a mass flow rate range of 0.05–0.14 kg s −1 . The half-angle of the hot tube was 3°; with six nozzles, the L/D 20; half angle conical splitter 45°.…”
Section: Introductionmentioning
confidence: 99%