1999
DOI: 10.1118/1.598781
|View full text |Cite
|
Sign up to set email alerts
|

Performance characteristics of a Kodak computed radiography system

Abstract: The performance characteristics of a photostimulable phosphor based computed radiographic (CR) system were studied. The modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE) of the Kodak Digital Science computed radiography (CR) system (Eastman Kodak Co.-model 400) were measured and compared to previously published results of a Fuji based CR system (Philips Medical Systems-PCR model 7000). To maximize comparability, the same measurement techniques and analysis me… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
36
0
2

Year Published

2000
2000
2022
2022

Publication Types

Select...
6
2
2

Relationship

1
9

Authors

Journals

citations
Cited by 55 publications
(40 citation statements)
references
References 9 publications
2
36
0
2
Order By: Relevance
“…A digitalization error (causing lack of reproducibility) of pixel values would be deleterious in these situations because it would attribute pixel values that differ from those corresponding to a true change that occurred in the patient. Apparently, photon noise originating from Xrays may be one factor that could contribute to the large digitalization error observed for photostimulable plates of the Digora system 4,6,17,18 . As observed in Table 2 through Table 5, the lower exposure times (0.3; 0.2; 0.1; 0.05 s) showed, in general, higher pixel variability.…”
Section: Discussionmentioning
confidence: 99%
“…A digitalization error (causing lack of reproducibility) of pixel values would be deleterious in these situations because it would attribute pixel values that differ from those corresponding to a true change that occurred in the patient. Apparently, photon noise originating from Xrays may be one factor that could contribute to the large digitalization error observed for photostimulable plates of the Digora system 4,6,17,18 . As observed in Table 2 through Table 5, the lower exposure times (0.3; 0.2; 0.1; 0.05 s) showed, in general, higher pixel variability.…”
Section: Discussionmentioning
confidence: 99%
“…35 " 38 Computing the two-dimensional (2D) NPS is important to study the presence or absence of any off-axis noise peaks. Since the computation time of computers is no longer a constraint, 35 computing the entire 2D NPS and estimating the one-dimensional (ID) NPS from the 2D NPS was used.…”
Section: B Noise Power Spectrum Measurementmentioning
confidence: 99%
“…의학영상을 획득하기 위하여 사용되는 진단영역의 방사선 에너지 대역은 40 kVp ~ 150 kVp의 범위를 사용하고 있다 [2] . 변조전달함수) [3] , 잡음력스펙트럼(noise power spectrum; NPS) [4] , 양자검출효율(detective quantum efficiency; DQE) [5] , RMS(Root Mean Square) [6] , 위너 스펙트럼 (Wiener spectrum), Entropy 등이 있다.…”
Section: ⅰ Introductionunclassified