2020
DOI: 10.3390/en13164272
|View full text |Cite
|
Sign up to set email alerts
|

Performance Comparison of PD Data Acquisition Techniques for Condition Monitoring of Medium Voltage Cables

Abstract: Already installed cables are aging and the cable network is growing rapidly. Improved condition monitoring methods are required for greater visibility of insulation defects in the cable networks. One of the critical challenges for continuous monitoring is the large amount of partial discharge (PD) data that poses constraints on the diagnostic capabilities. This paper presents the performance comparison of two data acquisition techniques based on phase resolved partial discharge (PRPD) and pulse acquisition (PA… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…According to the tests, RC-based sensors performed better than HFCTs because of their higher SNR. The design and performance characteristics of the RC and HFCT sensors were compared in [26] in order to measure the PD signals that are released from PD defects. These sensors were chosen for their operational behavior, installation potential around the cable shielding, and non-intrusive sensing ability.…”
Section: Comparative Analysis Of Sensorsmentioning
confidence: 99%
“…According to the tests, RC-based sensors performed better than HFCTs because of their higher SNR. The design and performance characteristics of the RC and HFCT sensors were compared in [26] in order to measure the PD signals that are released from PD defects. These sensors were chosen for their operational behavior, installation potential around the cable shielding, and non-intrusive sensing ability.…”
Section: Comparative Analysis Of Sensorsmentioning
confidence: 99%
“…The clarity in the interpretation of the measured quantities and their relationship with the aging mechanism or type of deterioration is vital for reliable diagnostics. Identification of the changing pattern as a reflection of progressing deterioration can provide a traceable behavior of insulation aging and prediction of its expected condition [16]. Due to stochastic characteristics of interest observed from the analyzed measurements, it is challenging to identify the degradation patterns.…”
Section: Introductionmentioning
confidence: 99%
“…PD measurements provide a direct illustration of the insulation conditions. Initial studies conducted by the authors demonstrate the characteristics of PD signals such as PD magnitude and pulse-repetition rate analyzed from the PDIV up to the breakdown of the insulation due to the gradual increase in electrical stress [16]. The variation in these characteristics provides a cognizable pattern during various stages of degradation.…”
mentioning
confidence: 99%
“…Moreover, obstacles exist in gaining access to or diagnosing cable conditions once the cable has been installed and is under operation. Various cable diagnosis methods have been developed including the DC withstand, VLF tan delta, and partial discharge diagnosis [1,2,3]. The DC withstand voltage test may be adequate for identifying insulation deterioration and detecting leakage currents.…”
Section: Introductionmentioning
confidence: 99%