2012 IEEE Vehicle Power and Propulsion Conference 2012
DOI: 10.1109/vppc.2012.6422634
|View full text |Cite
|
Sign up to set email alerts
|

Performance evaluation of Multilevel Converter based cell balancer with reciprocating air flow

Abstract: Abstract-The modeling and design of an active battery cell balancing system using Multilevel Converter (MLC) for EV/HEV/PHEV is studied under unidirectional as well as reciprocating air flow. The MLC allows to independently switch ON/OFF each battery cell in a battery pack. The optimal policy (OP ) exploiting this extra degree-of-freedom can achieve both temperature and state-of-charge (SoC) balancing among the cells. The OP is calculated as the solution to a convex optimization problem based on the assumption… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 27 publications
(35 reference statements)
0
2
0
Order By: Relevance
“…Electrical centrality use in a system changes after some time in light of changes in the power necessities of weight contraptions in like manner as the customers' practices. Weight following power plants (for example, non-supportable power source power plants [28] [7] ) are proposed to administer rapid changes in power demands on the power network. In addition, the system requires [18] a particular level of working store, which is incorporated turning and non-turning spares, to keep up a fundamental decent ways from power blackouts and brownouts.…”
Section: Introductionmentioning
confidence: 99%
“…Electrical centrality use in a system changes after some time in light of changes in the power necessities of weight contraptions in like manner as the customers' practices. Weight following power plants (for example, non-supportable power source power plants [28] [7] ) are proposed to administer rapid changes in power demands on the power network. In addition, the system requires [18] a particular level of working store, which is incorporated turning and non-turning spares, to keep up a fundamental decent ways from power blackouts and brownouts.…”
Section: Introductionmentioning
confidence: 99%
“…The coolant flow is assumed to be laminar with known inlet temperature and speed. In [21], only one configuration of the five-cell string was studied to evaluate the performance of the MLC-based cell balancer. A similar method was adopted in the present study.…”
Section: Introductionmentioning
confidence: 99%