The PTC performance was evaluated at four (i.e., 25o, 35o, 45o, and 55o) different adjusting Angles and it clearly showed that the adjusting Angles is highly significant, affecting the efficiency of the collector. The PTC received mean solar radiation 513 kJ.m-2.hr-1 with the absorbing temperature of the absorber in PTC was noted 123oC, 115oC, and 113oC consecutively the months of the year with the adjusting angles of 25o, 35o, and 45o respectively. Distilled water from the solar water distillation unit was found to improve the laboratory’s quality and wash equipment in the hospital. PTC’s efficiency noted 26.9%, 26.3%, and 26.1% with the distilled water up to 217, 313, and 343 ml.m-2.day-1 for the adjusting Angles of 25o, 45o, and 35o respectively. From the result, it concluded that to obtain maximum distilled water, the PTC should be set on adjusting Angles of 25o, 35o, and 45o. The average unit price of distillate from the solar still is assessed as Rs. 2.64/L-m2 with a payback period is 365 days. The unit distillate cost is seen to reduce significantly from Rs. 4.92/L to Rs. 1.57/L. It concluded from results that the distilled water of PTC relatively decent quality.