2021
DOI: 10.3390/app11083467
|View full text |Cite
|
Sign up to set email alerts
|

Performance Evaluation of rPPG Approaches with and without the Region-of-Interest Localization Step

Abstract: Traditionally, the first step in physiological measurements based on remote photoplethysmography (rPPG) is localizing the region of interest (ROI) that contains a desired pulsatile information. Recently, approaches that do not require this step have been proposed. The purpose of this study was to evaluate the performance of selected approaches with and without ROI localization step in rPPG signal extraction. The Viola-Jones face detector and Kanade–Lucas–Tomasi tracker (VK) in combination with (a) a region-of-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 46 publications
(104 reference statements)
0
3
0
Order By: Relevance
“…• Skin segmentation: Moreover, skin segmentation can be applied to catch skin pixels only without any background pixels [67,68]. • 1-D signal conversion: The video sequence is converted into a 1-D signal by averaging the intensity levels of the whole frame pixels or the localized pixels in the intended ROI [69]. So, we have three independent vectors arising from RGB channels.…”
Section: Camera-based Rppg Extraction Overviewmentioning
confidence: 99%
“…• Skin segmentation: Moreover, skin segmentation can be applied to catch skin pixels only without any background pixels [67,68]. • 1-D signal conversion: The video sequence is converted into a 1-D signal by averaging the intensity levels of the whole frame pixels or the localized pixels in the intended ROI [69]. So, we have three independent vectors arising from RGB channels.…”
Section: Camera-based Rppg Extraction Overviewmentioning
confidence: 99%
“…The evaluation metrics used to assess the performance of the proposed robot-aided contactless monitoring system consist of the following indicators: in [42], the absolute error is a performance accuracy indicator of the PPG methods and it is calculated as follows:…”
Section: Evaluation Metricsmentioning
confidence: 99%
“…Selecting appropriate ROI can effectively enhance the ruggedness of heart rate detection by IPPG [19][20]. The ROI ought to be capillary-rich, for instance, the frontal region of the face, the cheeks on the left and right, the lips and the chin, etc.…”
Section: Regions Of Interest Acquisitionmentioning
confidence: 99%