Performance evaluation of the MOLECUBES β-CUBE—a high spatial resolution and high sensitivity small animal PET scanner utilizing monolithic LYSO scintillation detectors

Abstract: The MOLECUBES β-CUBE scanner is the newest amongst commercially available preclinical PET scanners for dedicated small animal imaging. The scanner is compact, lightweight and utilizes a small footprint to facilitate bench-top imaging. It can be used individually, or in combination with the X-CUBE CT scanner, which provides the ability to perform all necessary PET data corrections and provide fully quantitative PET images. The PET detector comprises of an 8 mm thick monolithic LYSO scintillator read-out by an a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
144
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 123 publications
(145 citation statements)
references
References 40 publications
(47 reference statements)
1
144
0
Order By: Relevance
“…To evaluate the spatial resolution, the NEMA standard mandates the use of point source scans which are reconstructed using filtered backprojection. However, basically all modern PET scanners instead use an iterative maximum likelihood expectation maximization (MLEM) algorithm for reconstruction [5,6,7,8,9,10,4,11,12,13,14,15], so a scanner's spatial resolution using filtered backprojection is not necessarily indicative of its spatial resolution for applications. While the mandated filtered backprojection is intended to benchmark the detector performance alone, we will demonstrate in the following that it disadvantages certain scanner geometries.…”
Section: Spatial Resolutionmentioning
confidence: 99%
See 2 more Smart Citations
“…To evaluate the spatial resolution, the NEMA standard mandates the use of point source scans which are reconstructed using filtered backprojection. However, basically all modern PET scanners instead use an iterative maximum likelihood expectation maximization (MLEM) algorithm for reconstruction [5,6,7,8,9,10,4,11,12,13,14,15], so a scanner's spatial resolution using filtered backprojection is not necessarily indicative of its spatial resolution for applications. While the mandated filtered backprojection is intended to benchmark the detector performance alone, we will demonstrate in the following that it disadvantages certain scanner geometries.…”
Section: Spatial Resolutionmentioning
confidence: 99%
“…The Derenzo phantom is already well-established in the community as a benchmark to evaluate the spatial resolution. For instance, several NEMA performance publications already include such a measurement as a benchmark of spatial resolution [5,7,12,15]. However, these results are not easily comparable, as there currently isn't a standardized quantitative analysis method to determine the spatial resolution from a measurement of a Derenzo phantom.…”
Section: Spatial Resolutionmentioning
confidence: 99%
See 1 more Smart Citation
“…Detector block configurations which make use of monolithic crystals provide some advantages when compared to pixelated crystals and, therefore, make them good candidates for PET applications [18][19][20][21]. The crystal thickness and geometry, as well as treatments on the walls vary depending on the application.…”
Section: Introductionmentioning
confidence: 99%
“…Digital Object Identifier 10.1109/TRPMS.2018.2884320 the brain or female breast [4]- [6]. Recently, the advantages of DOI information have also been experimentally validated for a clinical case with a 70 cm diameter tomographic setup [7].…”
Section: Introductionmentioning
confidence: 99%