2013
DOI: 10.3343/alm.2013.33.3.184
|View full text |Cite
|
Sign up to set email alerts
|

Performance Evaluation of the OraQuick Hepatitis C Virus Rapid Antibody Test

Abstract: BackgroundA reliable rapid assay for hepatitis C virus (HCV) may be helpful in various clinical settings. We evaluated the performance of the OraQuick HCV Rapid Antibody Test (OraSure Technologies Inc., Bethlehem, PA, USA).MethodsClinical sensitivity and specificity were evaluated with oral fluids and sera from 137 patients diagnosed with hepatitis C and 300 healthy blood donors in a multi-center collaborative study. The stored sera of 200 proven HCV-infected patients and 200 healthy subjects were also evaluat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
65
0
2

Year Published

2015
2015
2021
2021

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 74 publications
(68 citation statements)
references
References 11 publications
1
65
0
2
Order By: Relevance
“…67 Only 5 µL of blood is required, which can be readily obtained via a finger prick. 72 Using oral fluid, the clinical sensitivity and specificity are 97.8% and 100%, respectively. 72 Testing based on oral fluid is less invasive, and medical personnel are protected from biohazards.…”
Section: Oraquick Hcv Rapid Antibody Testmentioning
confidence: 99%
See 3 more Smart Citations
“…67 Only 5 µL of blood is required, which can be readily obtained via a finger prick. 72 Using oral fluid, the clinical sensitivity and specificity are 97.8% and 100%, respectively. 72 Testing based on oral fluid is less invasive, and medical personnel are protected from biohazards.…”
Section: Oraquick Hcv Rapid Antibody Testmentioning
confidence: 99%
“…72 Using oral fluid, the clinical sensitivity and specificity are 97.8% and 100%, respectively. 72 Testing based on oral fluid is less invasive, and medical personnel are protected from biohazards. The lower sensitivity, however, poses challenges in low-prevalence settings.…”
Section: Oraquick Hcv Rapid Antibody Testmentioning
confidence: 99%
See 2 more Smart Citations
“…The reason for this may be the higher proportion of relatively low-titer reactive samples and the longer window period in the early phases of infection. However also for HbSAg and HCVAb there are kits that show promising results in terms of diagnostic accuracy [60][61][62][63][64][65] and a HbSAg RDT has been recently CE marked as it achieves the requested sensitivity of at least 0.125 I.U/mL [66].…”
Section: Transfusion Transmitted Infections -"Ttis"-screeningmentioning