2017
DOI: 10.1016/j.ijrefrig.2016.09.017
|View full text |Cite
|
Sign up to set email alerts
|

Performance improvement of air source heat pump using gas-injected rotary compressor through port on blade

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…The use of a cooling capacity control system forms an indispensable element in refrigeration systems, the duration of products at a specified temperature is defined on its basis [4]. This is a necessary element of a refrigeration system [5], although it leads to the decrease of the value of COP. The paper presents an approach taken to determine the COP coefficient for a refrigeration system coupled with a dedicated control system.…”
Section: Fig 1 Principle Of Operation Of a Typical Refrigeration Symentioning
confidence: 99%
See 1 more Smart Citation
“…The use of a cooling capacity control system forms an indispensable element in refrigeration systems, the duration of products at a specified temperature is defined on its basis [4]. This is a necessary element of a refrigeration system [5], although it leads to the decrease of the value of COP. The paper presents an approach taken to determine the COP coefficient for a refrigeration system coupled with a dedicated control system.…”
Section: Fig 1 Principle Of Operation Of a Typical Refrigeration Symentioning
confidence: 99%
“…The heat conducted through the walls of the container cannot be underestimated Q. On this basis, the power balance equation was derived in the form: = + + (2) The values of power delivered from the water tank and the power derived from the air inside the chamber are calculated on the basis of the measurements from the relations in (4) and (5). The power transmitted through the walls of the cooling chamber is calculated on the basis of the conduction law on the basis of equation (6).…”
Section: Laboratory Determination Of Copmentioning
confidence: 99%
“…The HTHP system model could be established and calculated using the outlet parameters calculated in the heat and mass transfer model. The ASHP system model could be established by relating the evaporation temperature to the ambient air temperature (Wang et al, 2017). Then, the COP of the HTHP system and the ASHP system under non-frost condition were determined by:…”
Section: Fig 4 P-h Diagram Of the Vapor Compression Heat Pump Cyclementioning
confidence: 99%
“…Scroll compressors have the advantages of simple structure, small volume, lower cost, and easier control, making them more suitable for micro CAES systems [16]. Emhardt et al [17] investigated the effects of different scroll geometric parameters on the performance of a constant wall thickness scroll expander, considering the use of variable wall thickness and its impact on performance.…”
Section: Introductionmentioning
confidence: 99%