2022
DOI: 10.1016/j.applthermaleng.2022.118056
|View full text |Cite
|
Sign up to set email alerts
|

Performance investigation of adsorption cooling and desalination systems employing thermally enhanced copper foamed bed coated with SAPO-34 and CPO-27(Ni)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 52 publications
0
6
0
Order By: Relevance
“…Researchers investigated designs and performances of ACSs for trucks, cars, buses, fishing boats, and locomotives. The integration of ACS with other systems was also addressed. ACS with adsorption desalination (AD) ,, and desiccant dehumidification , are most common. This could be a potential strategy to enhance the COP, but thermo-economic investigations are still scarce.…”
Section: Simulated and Demonstrated Practical Examples Of Application...mentioning
confidence: 99%
See 1 more Smart Citation
“…Researchers investigated designs and performances of ACSs for trucks, cars, buses, fishing boats, and locomotives. The integration of ACS with other systems was also addressed. ACS with adsorption desalination (AD) ,, and desiccant dehumidification , are most common. This could be a potential strategy to enhance the COP, but thermo-economic investigations are still scarce.…”
Section: Simulated and Demonstrated Practical Examples Of Application...mentioning
confidence: 99%
“…270−272 The integration of ACS with other systems was also addressed. ACS with adsorption desalination (AD) 257,264,273 and desiccant dehumidification 274,275 are most common. This could be a potential strategy to enhance the COP, but thermo-economic investigations are still scarce.…”
Section: Simulated and Demonstrated Practical Examples Of Application...mentioning
confidence: 99%
“…The numerical results showed good agreement with the experimental results. Additionally, the numerical model system of equations was validated in reference [20] with copper foamed beds coated with advanced adsorbents.…”
Section: Validationmentioning
confidence: 99%
“…A coated sorbent layer could be implemented to reduce the thermal resistance at the boundary of sorbent grains and the heat exchanger surface. The effect of using coated beds and packed beds on adsorption system performance was discussed in [24,25]. It was investigated that the coated bed thermal parameters can be improved with the optimal selection of the coating thickness, grain size, and highly conductive binder used.…”
Section: Introductionmentioning
confidence: 99%