Performance investigation of an independent dedicated outdoor air system for energy-plus houses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 22 publications
(7 citation statements)
references
References 16 publications
0
7
0
Order By: Relevance
“…The simulation process is illustrated in Figure 1. In this study, nonresidential buildings were analyzed based on the measurement data of the Jincheon ecofriendly energy town [31], and residential buildings were analyzed using simulation data derived from the measurement data [32] to calculate the power consumption data, heating load data, and hot water supply load data of the buildings. Meteorological data were analyzed using the Meteonorm software.…”
Section: Model Developmentmentioning
confidence: 99%
See 1 more Smart Citation
“…The simulation process is illustrated in Figure 1. In this study, nonresidential buildings were analyzed based on the measurement data of the Jincheon ecofriendly energy town [31], and residential buildings were analyzed using simulation data derived from the measurement data [32] to calculate the power consumption data, heating load data, and hot water supply load data of the buildings. Meteorological data were analyzed using the Meteonorm software.…”
Section: Model Developmentmentioning
confidence: 99%
“…The load data of residential buildings in a previous study were used to analyze the load of the residential buildings in this study [32]. The measurement data were analyzed to calculate the electricity consumption data of residential buildings, including the plug load.…”
Section: Thermal and Electric Loadsmentioning
confidence: 99%
“…Referring to previous research [2,15,16], the operation modes of the adopted DOAS are classified as four modes. These are represented by four regions divided by three lines, according to the thermodynamic conditions of the OA on the psychrometric chart shown in Figure 4.…”
Section: Doas With Parallel System Operation Modesmentioning
confidence: 99%
“…The DOAS is a ventilation system by introducing the minimum ventilation [14], and it is generally used to remove the latent heating load of the server room; therefore, it is regularly used with a parallel system to remove the sensible heating load, and due to the use of 100% outdoor air in the DOAS, it will raise the thermal loads of the server room. Therefore, it is commonly used the enthalpy wheel (EW) to recover heat from the exhaust air (EA) for energy saving, and as a result it shows energy-saving potentials compared to the conventional VAV systems [13,15].…”
Section: Introductionmentioning
confidence: 99%
“…19 shows two patterns in the moist and dry climate zones. In the moist climate zones, the energy consumption increased as the general outdoor temperature decreased, while in the dry climate zones, the energy consumption decreased as the outdoor temperature decreased, except in the climate zones 1A, 6A, and 6B.…”
mentioning