2011
DOI: 10.1016/j.nima.2011.03.012
|View full text |Cite
|
Sign up to set email alerts
|

Performance of a new LMRPC prototype for the STAR MTD system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…The TPC is filled with P10 gas (10% methane, 90% argon) regulated at 2 mbar above atmospheric pressure [91]. It can record the tracks of particles, measure their momenta, The Muon Telescope Detector (MTD) [95,96] is also based on MRPC technology [93]. The MTD can trigger on and identify muons based on its precise timing and modest position resolution [97], allowing measurements of dileptons through the di-muon channel.…”
Section: The Star Detectormentioning
confidence: 99%
See 1 more Smart Citation
“…The TPC is filled with P10 gas (10% methane, 90% argon) regulated at 2 mbar above atmospheric pressure [91]. It can record the tracks of particles, measure their momenta, The Muon Telescope Detector (MTD) [95,96] is also based on MRPC technology [93]. The MTD can trigger on and identify muons based on its precise timing and modest position resolution [97], allowing measurements of dileptons through the di-muon channel.…”
Section: The Star Detectormentioning
confidence: 99%
“…which consist of a stack of resistive plates (float glass of 0. The Muon Telescope Detector (MTD) [95,96] is also based on MRPC technology [93]. The MTD can trigger on and identify muons based on its precise timing and modest position resolution [97], allowing measurements of dileptons through the di-muon channel.…”
Section: The Star Detectormentioning
confidence: 99%
“…The σ MRPC of one pad of one MRPC module was about 53.82±1.4 ps in figure 9 for example, whose operation voltage on the positive and negative electrode was ±6.8 kV. This result also could be corrected for better level by the Time-Position (T-P) correction with the position detectors' information from the Si detector, which will be further studied [19,20].…”
Section: The Time Resolution Of T0 With Beam Particlementioning
confidence: 95%
“…Prototypes of such LMRPCs have been running for the last four years in STAR [2,3] and many important results were obtained [4,5]. A close-tofinal prototype of 6-gap LMRPC module had also been developed with excellent performances [6] in 2010. Since the working HV of 6-gap LMRPC module is close to the limit of the HV supply in STAR, a new LMRPC prototype with 5 gas gaps with lower working HV has been developed and the performance has been measured with cosmic rays.…”
Section: Jinst 7 P10006mentioning
confidence: 99%
“…Figure 1 shows the structure of the 5-gap LMRPC module. It is the same structure as that of 6-gap LMRPC module [6] but with 1 gap less.…”
Section: Jinst 7 P10006mentioning
confidence: 99%