2011
DOI: 10.1109/tasc.2010.2090116
|View full text |Cite
|
Sign up to set email alerts
|

Performance of a ${\rm Nb}_{3}{\rm Sn}$ Quadrupole Under High Stress

Abstract: Abstract-Future upgrades of the Large Hadron Collider (LHC)will require large aperture and high gradient quadrupoles. Nb 3 Sn is the most viable option for this application but is also known for its strain sensitivity. In high field magnets, with magnetic fields above 12 T, the Lorentz forces will generate mechanical stresses that may exceed 200

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
17
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 30 publications
(18 citation statements)
references
References 8 publications
1
17
0
Order By: Relevance
“…The Protection Heater efficiency has been measured completing data from HQ02a. For the first time CLIQ system has been tested on Nb 3 Sn quadrupole. The test has proved the feasibility of the system to protect such short length magnet.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The Protection Heater efficiency has been measured completing data from HQ02a. For the first time CLIQ system has been tested on Nb 3 Sn quadrupole. The test has proved the feasibility of the system to protect such short length magnet.…”
Section: Discussionmentioning
confidence: 99%
“…The HQ magnet structure has been used in two different assemblies, HQ01 and HQ02 with two generations of Nb 3 Sn coils [1]- [3]. The HQ cross-section is shown in Fig.…”
Section: Indexmentioning
confidence: 99%
“…This has been proven recently on modern, high-J c Nb 3 Sn wires [78], confirming that the large observed degradation in single-wire measurements quoted earlier is a measurement artifact. A defining test of the US LHC Accelerator R&D Program (LARP) TQS03 magnet at CERN [79], in which the magnet was preloaded up to 260 MPa in the windings while experiencing very limited permanent degradation, re-established Nb 3 Sn firmly as the conductor of choice for future upgrades of the LHC.…”
Section: Transverse Pressure On Cablesmentioning
confidence: 99%
“…The HQ quadrupole magnet follows several successful tests of Nb Sn quadrupole magnets (a 90 mm aperture 1-meter long Technology Quadrupole (TQ) and a 3.6-meter Long Quadrupole (LQ) [1], [2]. HQ's 120 mm aperture is the first Nb Sn quadrupole magnet with alignment between coils and support structure.…”
Section: Introductionmentioning
confidence: 99%