2001
DOI: 10.1016/s0168-9002(01)00354-0
|View full text |Cite
|
Sign up to set email alerts
|

Performance of an elliptically polarized undulator beamline

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2004
2004
2020
2020

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…The high-voltage pulse produced a large interference of the ion-detection system in the region of small mass (m/z ≤ 2 u); the mass spectra were recorded for only m/z > 2 u. X-rays were provided from Taiwan Light Source, undulator beamline BL05B1. 25 The resolutions of X-rays were about 80, 70, and 150 meV at the carbon, nitrogen, and oxygen K-edges, respectively. The resolutions for the isotopic experiments were about 160, 140, and 300 meV at the carbon, nitrogen, and oxygen K-edges, respectively.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
See 2 more Smart Citations
“…The high-voltage pulse produced a large interference of the ion-detection system in the region of small mass (m/z ≤ 2 u); the mass spectra were recorded for only m/z > 2 u. X-rays were provided from Taiwan Light Source, undulator beamline BL05B1. 25 The resolutions of X-rays were about 80, 70, and 150 meV at the carbon, nitrogen, and oxygen K-edges, respectively. The resolutions for the isotopic experiments were about 160, 140, and 300 meV at the carbon, nitrogen, and oxygen K-edges, respectively.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…The experiments were performed with a homemade, orthogonal-acceleration, reflectron, time-of-flight, mass spectrometer (OA-R-TOF MS). 24 A diffusive molecular beam was generated from an orifice of a sample cell (stainless steel) near 300 K. Soft X-rays from a synchrotron 25 were directed into the ionization chamber with two bendable refocusing Kirkpatrick− Baez mirrors coated with Au. The X-rays crossed the diffusive molecular beam about 2 mm downstream from the orifice of the sample cell.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
See 1 more Smart Citation
“…As details of the synchrotron radiation beamline have been reported, 48 only a brief description is provided here. This beamline delivers >10 12 photons/s with energy in the 60−1400 eV range.…”
Section: ■ Experimentsmentioning
confidence: 99%
“…These experiments were performed at undulator beamline BL05B1 at the Taiwan Light Source, details of which have been reported previously; 23 only a brief description is presented here. This beamline delivers >10 12 photons s −1 with energies of 60− 1400 eV.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%