Abstract:Concrete filled steel tube (CFST) truss girder usually consists of CFST chords and hollow braces. The performance of steel tube truss girders filled with self-compacting concrete was investigated in this study. A total of eight CFST truss girders (Warren-vertical truss) specimens were tested. The main parameters were the concrete compressive strength and adding a reinforced bar in the concrete core of the bottom chord. Two of specimens without reinforcement were suggested as reference specimens. This study sho… Show more
“…ширины примыкания элементов, конструктивной увязки узла. Необходимость разработки методики расчета усиленных узлов путем внутреннего заполнения стального сечения бетоном отмечается в работах [18][19][20][21][22].…”