Performance of HR-pQCT, DXA, and FRAX in the discrimination of asymptomatic vertebral fracture in postmenopausal Chinese women

Abstract: Summary Volumetric bone density (vBMD) and trabecular microarchitecture measured by high-resolution peripheral quantitative computed tomography (HR-pQCT) can discriminate the patients with high risk of asymptomatic vertebral fracture (VF) in postmenopausal Chinese women. These findings suggested that HR-pQCT could provide additional information on bone quality of the patients with asymptomatic VF. Introduction Although ther… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 46 publications
(64 reference statements)
1
6
0
Order By: Relevance
“…The distal radius and distal tibia (non-dominant and non-fractured) of participants were scanned by HR-pQCT (XtremeCT I, Scanco Medical AG, Switzerland) using the standard scanning protocol (60 kVp, 900 μA, 100 ms integration time, isotropic voxel size 82 μm). The details of the HR-pQCT operational procedures and the image quality grading of HR-pQCT for motion artifact were illustrated in previous studies ( 18 , 19 ). Daily phantom calibration was performed to monitor the stability of the HR-pQCT system.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The distal radius and distal tibia (non-dominant and non-fractured) of participants were scanned by HR-pQCT (XtremeCT I, Scanco Medical AG, Switzerland) using the standard scanning protocol (60 kVp, 900 μA, 100 ms integration time, isotropic voxel size 82 μm). The details of the HR-pQCT operational procedures and the image quality grading of HR-pQCT for motion artifact were illustrated in previous studies ( 18 , 19 ). Daily phantom calibration was performed to monitor the stability of the HR-pQCT system.…”
Section: Methodsmentioning
confidence: 99%
“…Trabecular thickness (Tb.Th, mm) was derived by standard histomorphometry methods ( 24 ). For cortical bone analysis, cortical thickness was measured directly by a distance-transform method and intracortical pores in the binary cortex image were eliminated ( 19 ). Bone strength was estimated in terms of stiffness (kN/mm) by micro-finite element analyses (μFEA) on three-dimensional images of the distal radius and tibia using a built-in Image Processing Language software of HR-pQCT (IPL-FE v1.15, Scanco Medical).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations