2016
DOI: 10.3348/kjr.2016.17.4.489
|View full text |Cite
|
Sign up to set email alerts
|

Performance of Screening Mammography: A Report of the Alliance for Breast Cancer Screening in Korea

Abstract: ObjectiveTo analyze the diagnostic accuracy and trend in screening mammography in Korea.Materials and MethodsWe retrospectively linked the information from hospitals participating in the Alliance of Breast Cancer Screening in Korea (ABCS-K) and the database of the National Cancer Screening Program. We calculated performance indicators, including the recall rate, cancer detection rate (CDR), positive predictive value (PPV), sensitivity, specificity, false-positive rate (FPR), and interval cancer rate (ICR). Cha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
36
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 34 publications
(37 citation statements)
references
References 14 publications
0
36
0
1
Order By: Relevance
“…The performance indicators were defined in our previous report (11). We analyzed all data by age, breast density, and the number of visits to the same institution; we calculated odds ratios (ORs) (both crude [cORs] and adjusted [aORs], with 95% confidence intervals).…”
Section: Methodsmentioning
confidence: 99%
“…The performance indicators were defined in our previous report (11). We analyzed all data by age, breast density, and the number of visits to the same institution; we calculated odds ratios (ORs) (both crude [cORs] and adjusted [aORs], with 95% confidence intervals).…”
Section: Methodsmentioning
confidence: 99%
“…Thanks to the implementation of digital mammography, additional diagnostic accuracy can be achieved for specific subgroups of women, presumably from its superior ability to depict cancers in dense breast tissue . However, MX is an imperfect tool in detecting breast cancer, with an overall sensitivity of 75%‐85%, dropping as low as 30%‐50% in women with a BRCA gene mutation . Specificity is limited, and the positive predictive value of a biopsy recommendation is in the 25%‐45% range .…”
Section: Introductionmentioning
confidence: 99%
“…Specificity is limited, and the positive predictive value of a biopsy recommendation is in the 25%‐45% range . As many as 20%‐30% of breast cancers will not be detected on a mammogram . Mammographic sensitivity decreases with the increasing of parenchyma density due to a superimposition of dense breast tissue on a two‐dimensional (2D) mammographic projection.…”
Section: Introductionmentioning
confidence: 99%
“…Regarding the DTA studies, one reviewer experienced in DTA studies selected eligible articles according to criteria established elsewhere ( 9 ) with additional confirmation by another DTA expert in cases of ambiguity. Of the initial 124 candidate articles, 63 articles ( 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 ) were finally included. Regarding the studies that analyzed reliability, eligible articles were chosen by consensus after review by two of four independent reviewers experienced in the relevant methodology.…”
Section: Methodsmentioning
confidence: 99%