2016
DOI: 10.1016/j.nima.2016.09.024
|View full text |Cite
|
Sign up to set email alerts
|

Performance of the PRAXyS X-ray polarimeter

Abstract: The performance of the Time Projection Chamber (TPC) polarimeter for the Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) Small Explorer was evaluated using polarized and unpolarized X-ray sources. The PRAXyS mission will enable exploration of the universe through X-ray polarimetry in the 2-10 keV energy band. We carried out performance tests of the polarimeter at the Brookhaven National Laboratory, National Synchrotron Light Source (BNL-NSLS) and at NASA's Goddard Space Flight Center. The pol… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 27 publications
(25 citation statements)
references
References 20 publications
0
24
1
Order By: Relevance
“…Other TPCs that emphasize image reconstruction, in astronomy and applied science, involve x-ray polarimetry through the accurate reconstruction of the photoelectron (e.g. [413][414][415][416]), γ-ray polarimetry through pair production [77], Compton Cameras [417] and thermal neutron detectors [418]. They are particularly synergetic with many TPCs described in this review.…”
Section: Other Tpc Typesmentioning
confidence: 99%
“…Other TPCs that emphasize image reconstruction, in astronomy and applied science, involve x-ray polarimetry through the accurate reconstruction of the photoelectron (e.g. [413][414][415][416]), γ-ray polarimetry through pair production [77], Compton Cameras [417] and thermal neutron detectors [418]. They are particularly synergetic with many TPCs described in this review.…”
Section: Other Tpc Typesmentioning
confidence: 99%
“…Refs. 3,14,23,24). However, it is complicated to optimize a cut region in the two (or more) parameter plane (or space).…”
Section: Track Selection To Improve Sensitivitymentioning
confidence: 99%
“…The TPC design was proposed on board GEMS [68][69][70][71][72] and PRAXyS [73][74][75][76] mission proposals. The GPD design was proposed in the past in many mission proposals (the most relevant are: IXO [77], NHXM [78], POLARIX [79], ESA Medium class mission XIPE [80]) and currently in the IXPE mission [81,82] approved by NASA and eXTP mission [83] selected as background mission 1 by the Chinese Academy of Sciences.…”
Section: Photoelectric Polarimetersmentioning
confidence: 99%