2008
DOI: 10.1016/j.nima.2008.08.137
|View full text |Cite
|
Sign up to set email alerts
|

Performance of the prototype module of the GlueX electromagnetic barrel calorimeter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
13
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 23 publications
(15 citation statements)
references
References 9 publications
2
13
0
Order By: Relevance
“…The narrow peak requires resolution of ∼ 0.05/ √ E for incident γ, e ± , which is compatible with photon test beam results for similar spaghetti calorimeters [18]. The middle panel of Fig.…”
Section: Jet Finding and Energy Scalesupporting
confidence: 84%
“…The narrow peak requires resolution of ∼ 0.05/ √ E for incident γ, e ± , which is compatible with photon test beam results for similar spaghetti calorimeters [18]. The middle panel of Fig.…”
Section: Jet Finding and Energy Scalesupporting
confidence: 84%
“…Surrounding the tracking devices inside the solenoid is the Barrel Calorimeter (BCAL) [15,16], which covers polar angles between 12…”
mentioning
confidence: 99%
“…The term c /E results from noise and pileup in high-rate environments. Measurements of an early full-length prototype 3 using a photon beam [11] provided expectations for the various contributions to the resolution: a ≈ 5.4% √ GeV, b ≈ 2.3% and c negligible. The azimuthal angular resolution is dominated by the readout granularity in azimuth, which is about 2 cm.…”
Section: Bcal: Overview and Designmentioning
confidence: 99%