1995
DOI: 10.1016/0021-9673(95)00059-v
|View full text |Cite
|
Sign up to set email alerts
|

Perfusion immunoassay for acetylcholinesterase: analyte detection based on intrinsic activity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

1996
1996
2010
2010

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 11 publications
0
9
0
Order By: Relevance
“…Depending on the desired level of detection, UV/visible absorbance, fluorescence and MS have all been used for detecting analytes in the on/off mode of IAC. Specific examples of analytes that have been measured by this approach include human serum albumin [59,60], recombinant tissue-type plasminogen activator [61], recombinant antithrombin III [61], IgG [59,62], Escherichia coli [63], isoproturon [64], phenylurea herbicides [64,65], benzidine [66], dichlorobenzidine [66], aminoazobenzene [66], azo dyes [66], triazine [65], diethylstilbestrol [67], acetylcholinesterase [68], transferrin [69] and insulin [70]. …”
Section: Formats and Applications Of Iacmentioning
confidence: 99%
“…Depending on the desired level of detection, UV/visible absorbance, fluorescence and MS have all been used for detecting analytes in the on/off mode of IAC. Specific examples of analytes that have been measured by this approach include human serum albumin [59,60], recombinant tissue-type plasminogen activator [61], recombinant antithrombin III [61], IgG [59,62], Escherichia coli [63], isoproturon [64], phenylurea herbicides [64,65], benzidine [66], dichlorobenzidine [66], aminoazobenzene [66], azo dyes [66], triazine [65], diethylstilbestrol [67], acetylcholinesterase [68], transferrin [69] and insulin [70]. …”
Section: Formats and Applications Of Iacmentioning
confidence: 99%
“…Irth et al presented different strategies to accomplish immunochemical interactions in on-line post-column detection techniques (Irth et al, 1995). Either labeled antibodies (Irth et al, 1993;Oosterkamp et al, 1994aOosterkamp et al, 1998Irth et al, 1995;Miller and Herman, 1996;Cho et al, 1996) or labeled antigens (Oosterkamp et al, 1994b;Irth et al, 1995;Vanderlaan et al, 1995;Oosterkamp et al, 1996aOosterkamp et al, , 1996bOosterkamp et al, , 1997aOosterkamp et al, , 1997bCho et al, 1996) can be used to detect analytes eluting from the HPLC column. Bound and unbound labeled antibodies or labeled antigens are separated prior to detection.…”
Section: Post-column Immunoassay Coupled To Lcmentioning
confidence: 99%
“…Other formats of immunoassay used in the postcolumn mode include direct detection immunoassays (Vanderlaan et al, 1995;Cho et al, 1996), one-site immunoassays (Irth et al, 1993(Irth et al, , 1995Oosterkamp et al, 1994aOosterkamp et al, , 1997aOosterkamp et al, , 1998Miller and Herman, 1996), sandwich immunoassays (Cho et al, 1996) and competitive binding immunoassays (Oosterkamp et al, 1994b(Oosterkamp et al, , 1996a(Oosterkamp et al, , 1996b(Oosterkamp et al, , 1997a(Oosterkamp et al, , 1997bIrth et al, 1995;Shahdeo and Karnes, 1999;Shahdeo et al, 2000;Graefe et al, 2000).…”
Section: Post-column Immunoassay Coupled To Lcmentioning
confidence: 99%
See 1 more Smart Citation
“…Fluorescein-labeled F ab fragments (raised against digoxigenin) and immobilized digoxin were used in this postcolumn detection system. Related methods based on direct detection or sandwich immunoassays have been used to monitor acetylcholinesterase and bovine growth hormone releasing factor (36,37). A competitive binding immunoassay has not formally been used for postcolumn detection, but such an approach has been demonstrated in principle with other affinity systems, such as the binding of avidin to biotin (35).…”
Section: P Po Os St Tc Co Ol Lu Um Mn N I Im Mm Mu Un No Od De Et Te mentioning
confidence: 99%