2019
DOI: 10.1016/j.clinph.2019.04.718
|View full text |Cite
|
Sign up to set email alerts
|

Periodic focal epileptiform discharges

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 52 publications
0
9
0
Order By: Relevance
“…LPDs were recorded when synchronized periodic ECoG discharges with an amplitude of more than 600 to 800 µV appeared on an area of the lateral temporal lobe of more than 10 cm 2 , which is consistent with previous findings. 10,12,13,19 On ECoG, both the SW polyspikes in patient 1 and the PD spike components with various peaks in patient 2 were recorded as monophasic sharp waves on EEG, which reflects a “smearing effect.” 13 In contrast, a subsequent slow wave in patient 1 was clearly recorded on EEG. This was probably based on the fact that cortical potentials are not substantially attenuated on the scalp for components below 15 Hz, while the 15 to 30 Hz components show clear attenuation.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…LPDs were recorded when synchronized periodic ECoG discharges with an amplitude of more than 600 to 800 µV appeared on an area of the lateral temporal lobe of more than 10 cm 2 , which is consistent with previous findings. 10,12,13,19 On ECoG, both the SW polyspikes in patient 1 and the PD spike components with various peaks in patient 2 were recorded as monophasic sharp waves on EEG, which reflects a “smearing effect.” 13 In contrast, a subsequent slow wave in patient 1 was clearly recorded on EEG. This was probably based on the fact that cortical potentials are not substantially attenuated on the scalp for components below 15 Hz, while the 15 to 30 Hz components show clear attenuation.…”
Section: Discussionmentioning
confidence: 99%
“…Third, as in our previous reports, [13][14][15] the cortical source area was calculated based on 1 cm 2 per electrode contact, which can overestimate the source area. To minimize this problem, Tatum et al 19 used high-density ECoG electrodes to demonstrate that the minimum area required to capture PDs was 1.5 to 3 cm at a single gyrus during awake craniotomy. Fourth, during chronic subdural electrode recording, it is necessary to recognize that EEG recording conditions are not physiological.…”
Section: Discussionmentioning
confidence: 99%
“…Nossek et al also report failure rates of awake ECS, with one case series reporting 12.6% experiencing intraoperative seizures and 2.3% failing due to these seizures, and in another series, they report an overall failure rate of 6.4% for awake craniotomy, with 2.1% failing due to seizures, and 4.2% falling due to lack of communication during the mapping . In a retrospective analysis, Tatum et al reported that 5.7% of patients had seizures during ECS . The seizure rate in this report (14.08%) differs from those reported in previous studies, but this includes both aborted/failed ECS as well as limited/incomplete ECS mapping, as we included two cases in which ECS was planned but not attempted due to a generalized seizure occurring prior to ECS deployment.…”
Section: Discussionmentioning
confidence: 53%
“…39,40 In a retrospective analysis, Tatum et al reported that 5.7% of patients had seizures during ECS. 41 The seizure rate in this report (…”
Section: Ecs Failure Ratesmentioning
confidence: 68%
See 1 more Smart Citation