2020
DOI: 10.1016/j.jacep.2020.02.005
|View full text |Cite
|
Sign up to set email alerts
|

Periprocedural Management of Cardiac Tamponade During Catheter Ablation for AF Under Uninterrupted DOAC and Warfarin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 14 publications
0
6
0
Order By: Relevance
“…All ablation procedures including PVI were performed under the guidance of the 3D-electroanatomical mapping system (CARTO, Biosense Webster) with an LA geometry obtained from the CT image [ 13 ]. Intravenous heparin (100 IU/kg) was administered immediately after the puncture and was added properly to maintain an activated clotting time of 300–350 s during the procedure [ 14 , 15 ]. We used a 3.5 mm tip, open-irrigated contact force sensing ablation catheter (25–35 W, 42 °C, irrigation flow rate of 17–30 mL/min; Navistar ThermoCool SmartTouch, Biosense Webster, Inc.), a circular mapping catheter for PVI (Lasso, Biosense Webster, Inc., USA), and a multi-electrode mapping catheter for 3D-electroanatomical mapping (PentaRay, Biosense Webster, Inc., USA) [ 13 ].…”
Section: Methodsmentioning
confidence: 99%
“…All ablation procedures including PVI were performed under the guidance of the 3D-electroanatomical mapping system (CARTO, Biosense Webster) with an LA geometry obtained from the CT image [ 13 ]. Intravenous heparin (100 IU/kg) was administered immediately after the puncture and was added properly to maintain an activated clotting time of 300–350 s during the procedure [ 14 , 15 ]. We used a 3.5 mm tip, open-irrigated contact force sensing ablation catheter (25–35 W, 42 °C, irrigation flow rate of 17–30 mL/min; Navistar ThermoCool SmartTouch, Biosense Webster, Inc.), a circular mapping catheter for PVI (Lasso, Biosense Webster, Inc., USA), and a multi-electrode mapping catheter for 3D-electroanatomical mapping (PentaRay, Biosense Webster, Inc., USA) [ 13 ].…”
Section: Methodsmentioning
confidence: 99%
“…Cardiac tamponade, a major life-threatening complication, has been evaluated as a representative bleeding event in previous uninterrupted DOAC with CA studies. 21,22 In those studies, the frequency of cardiac tamponade under CA for AF with uninterrupted DOAC ranged from 0% (0/123) to 1.6% (1/64), with a mean of 0.66% (22/3,323). 21, 22 Currently, an incidence of cardiac tamponade of <1% seems to be acceptable during CA for AF.…”
Section: Discussionmentioning
confidence: 97%
“…Patients continued anticoagulant therapy for at least 3 weeks before the ablation procedure. Anticoagulant drugs including vitamin K antagonists and direct oral anticoagulants were uninterruptedly administered throughout the procedure [ 15 ].…”
Section: Methodsmentioning
confidence: 99%