2018
DOI: 10.1093/europace/euy058
|View full text |Cite
|
Sign up to set email alerts
|

Permanent His-bundle pacing: a systematic literature review and meta-analysis

Abstract: Among 26 articles of permanent HBP, the implant success rate averaged 84.8% and LVEF improved by an average of 5.9% during follow-up. Specific reporting of our clinical outcomes of interest varied widely, highlighting the need for uniform reporting in future HBP trials.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

10
153
1
9

Year Published

2019
2019
2022
2022

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 204 publications
(173 citation statements)
references
References 36 publications
10
153
1
9
Order By: Relevance
“…After the first 40 implants at a center, the success rate was higher at 87%. Other present‐day reports of HBP success rates are consistent with this, ranging from 80% to 92% . Some hospitals did not have comprehensive success rate data and it is conceivable that their rates may have been lower.…”
Section: Discussionsupporting
confidence: 73%
See 1 more Smart Citation
“…After the first 40 implants at a center, the success rate was higher at 87%. Other present‐day reports of HBP success rates are consistent with this, ranging from 80% to 92% . Some hospitals did not have comprehensive success rate data and it is conceivable that their rates may have been lower.…”
Section: Discussionsupporting
confidence: 73%
“…The HBP pioneers encountered several challenges during the early years of HBP, such as low procedural success rates and high and rising thresholds . However, with the arrival of specialized delivery equipment and a more suitable pacing lead, the published HBP success rates appear to have improved . This published experience includes relatively small numbers of patients from a limited number of expert centers.…”
Section: Introductionmentioning
confidence: 99%
“…This approach was technically challenging, time and fluoro consuming. The technical issues observed during the early HBP experience has been partially overcome by the dedicated pacing lead (SelectSecure 3830; Medtronic, Minneapolis, Minnesota) and sheaths (C315His; C304 SelectSite; Medtronic) 7,8,13 . As a matter of a fact, over the recent years, a growing body of evidence has stated the clinical benefits of HBP 3,13–15 .…”
Section: Discussionmentioning
confidence: 99%
“…The technical issues observed during the early HBP experience has been partially overcome by the dedicated pacing lead (SelectSecure 3830; Medtronic, Minneapolis, Minnesota) and sheaths (C315His; C304 SelectSite; Medtronic) 7,8,13 . As a matter of a fact, over the recent years, a growing body of evidence has stated the clinical benefits of HBP 3,13–15 . Abdelrahman et al 16 have highlighted the superiority of HBP compared with the traditional RV pacing sites in terms of a combined end point including all‐cause mortality, HF hospitalizations and upgrading to cardiac resynchronization therapy, during a mean follow‐up of 2 years.…”
Section: Discussionmentioning
confidence: 99%
“…Permanent HBP has been performed for two decades in patients undergoing AV‐node ablation, 23–25 in patients with narrow QRS and normal His‐Purkinje conduction, 26,27 and in those with bundle branch block and complete nodal and infranodal block 28–30 . However, its adoption in patients with heart failure who are candidates for CRT has emerged only in recent years.…”
Section: Discussionmentioning
confidence: 99%