Handbook of Analytical Techniques in Concrete Science and Technology 2001
DOI: 10.1016/b978-081551437-4.50019-9
|View full text |Cite
|
Sign up to set email alerts
|

Permeation Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
40
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(42 citation statements)
references
References 34 publications
2
40
0
Order By: Relevance
“…Autoclam device from Amphora Company was used to measure the Air Permeability Index (API) [32]. The modification of the API test procedure involves applying of an annular seal, between the base ring and the concrete surface, made of microgum with a thickness of 8 mm, and also clamping a steel ring with G-clamps instead of using expansion anchors in the bored holes.…”
Section: Specimens and Test Methodsmentioning
confidence: 99%
“…Autoclam device from Amphora Company was used to measure the Air Permeability Index (API) [32]. The modification of the API test procedure involves applying of an annular seal, between the base ring and the concrete surface, made of microgum with a thickness of 8 mm, and also clamping a steel ring with G-clamps instead of using expansion anchors in the bored holes.…”
Section: Specimens and Test Methodsmentioning
confidence: 99%
“…After 4 days, a further quarter of the depth was immersed before complete immersion after another 2 days. The whole process is shown in Figure 1, which allowed the specimens to be saturated by capillary action without trapping air [20]. At the completion of the saturation process, the saturated mass (Mo) and the dimensions (radius, r and length, l) were measured.…”
Section: Specimen Preparationmentioning
confidence: 99%
“…Relative humidity (RH) provides direct information about the content and distribution of moisture in the concrete sample and is considered a useful parameter in checking the reliability of an air permeability measurements; particularly when distinguishing between pore structure and moisture affects [14,16,20,21]. In this study, RH measurements were carried out on sample surfaces and within drilled 20 mm deep holes using an RH probe, which is shown in Figure 2.…”
Section: Relative Humidity On the Surface And In The 20mm Drilled Holementioning
confidence: 99%
See 1 more Smart Citation
“…In concrete, physical structure (distribution and pores size) as well as water condition inside these pores, influence the transportation process (Muhammed Basheer, 2001).…”
Section: Introductionmentioning
confidence: 99%