Abstract:Aim: To develop an automated system to monitor sedation levels in intensive care unit patients using heart rate variability (HRV).Methods: We developed an automatic sedation level prediction system using HRV as input to a support vector machine learning algorithm. Our data consisted of electrocardiogram recordings from a heterogeneous group of 50 mechanically ventilated adults receiving sedatives in an ICU setting. The target variable was the Richmond agitation-sedation scale score, grouped into four levels: "… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.