2002
DOI: 10.2116/analsci.18.301
|View full text |Cite
|
Sign up to set email alerts
|

Perspectives of Carbon Paste Electrodes in Stripping Potentiometry

Abstract: Experimental ApparatusAn AUTOLAB PGSTAT 10 system equipped with ECD-MODUL and controlled by GPES software (Ecochemie, Utrecht, Holland) was used in combination with an electrode stand (Metrohm, Switzerland) adapted for measurements with CPEs. Besides a CPE (see below), the electrode cell involved also a Pt-wire auxiliary and an Ag/AgCl reference electrode (saturated solution of KCl; Metrohm, Switzerland). Stirring was performed with a Teflon-coated bar at approx. 100 rpm using a magnetic stirrer (Model E 405, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
3

Year Published

2004
2004
2016
2016

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 22 publications
(16 citation statements)
references
References 21 publications
0
13
0
3
Order By: Relevance
“…Grafit digunakan sebagai bahan elektroda karena mempunyai daya hantar listrik yang baik, bersifat inert, dan memiliki rentang potensial yang lebar. Parafin cair digunakan sebagai pengikat karena dalam pengukuran tidak ikut bereaksi (inert) dan stabil dalam campuran (Svancara et al, 2002). Penggunaan eter mahkota yang sebelumnya hanya digunakan sebagai modifier dalam analisis logam alkalidan ion logam transisi, diharapkan dapat digunakan sebagai modifier untuk analisis senyawa organik seperti asam askorbat.…”
Section: Pendahuluanunclassified
“…Grafit digunakan sebagai bahan elektroda karena mempunyai daya hantar listrik yang baik, bersifat inert, dan memiliki rentang potensial yang lebar. Parafin cair digunakan sebagai pengikat karena dalam pengukuran tidak ikut bereaksi (inert) dan stabil dalam campuran (Svancara et al, 2002). Penggunaan eter mahkota yang sebelumnya hanya digunakan sebagai modifier dalam analisis logam alkalidan ion logam transisi, diharapkan dapat digunakan sebagai modifier untuk analisis senyawa organik seperti asam askorbat.…”
Section: Pendahuluanunclassified
“…This was shown already in the first years of a new millennium; e.g., a former procedure elaborated for the determination of thallium [333] could be adapted for gold (as tetrachloroaurate [99,331]), or iodide [101,331], and the perspectives of stripping potentiometry with CPEs, focused on the role of pasting liquid, were thus outlined as quite promising; especially, for some determinations in samples with extremely complex matrices (e.g., iodide in non-pretreated and solely diluted urine [334]). As already shown in the previous section 3.4.1., another recently frequent application of CPEs in stripping potentiometry is their use as the electrode support for metallic films; the advantage of application being again that the electrode surface can easily be renewed compared to metallic film electrodes on solid supports [244,247,249,[344][345][346].…”
Section: Stripping (Chrono)potentiometrymentioning
confidence: 99%
“…As already shown in the previous section 3.4.1., another recently frequent application of CPEs in stripping potentiometry is their use as the electrode support for metallic films; the advantage of application being again that the electrode surface can easily be renewed compared to metallic film electrodes on solid supports [244,247,249,[344][345][346]. Simultaneously, a series of methods was presented; namely, the determination of lead and cadmium [244,334] or copper [334] when using the MF-CPE configurations, copper and mercury [336] or arsenic [247] at AuF-CPEs, as well as lead and cadmium in parallel at either BiF-CPEs [244,249] or SbF-CPEs [273,337].…”
Section: Stripping (Chrono)potentiometrymentioning
confidence: 99%
“…All other chemicals used such as acetonitrile, NaTPB and supporting electrolytes (LiClO 4 , Bu 4 NPF 6 and Bu 4 NCl 4 ) were analytical grade reagent (Merk and Fluka). In voltammetric determination the solutions were dearated with purified Argon.…”
Section: Reagents and Solutionsmentioning
confidence: 99%
“…and the background voltammogram was recorded by scanning the potential toward the positive direction using the selected waveform [5] then 1 ml 5x10 -2 mol/L of the investigated solution was introduced to the electrolysis cell and the produced voltammogram was recorded. The previous procedure has been repeated with both Bu 4 NPF 6 and Bu 4 NCl 4 as supporting electrolytes where the electrode should be polished before each measurement [6].…”
Section: Effect Of Supporting Electrolytementioning
confidence: 99%