SPE Annual Technical Conference and Exhibition 2004
DOI: 10.2118/89870-ms
|View full text |Cite
|
Sign up to set email alerts
|

Petrozuata - An Application of Multiphase Metering Technology

Abstract: The application of Multiphase Meters (MPM) over the past decade or so has, in the main, been in deployment of meters in small quantities (i.e. ones and twos) and there are few applications where MPM's have been deployed in bulk. Petrozuata in Venezuela is such an operation where 37 MPM's were deployed and have been in use for over 5 years. This paper describes the facility and the operations where MPM's have been selected, tested and implemented. The paper also describes the difficulties expe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2005
2005
2013
2013

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 7 publications
0
7
0
Order By: Relevance
“…This multiphase meter can measure oil, water and gas in production streams with gas volume fraction of less than 25%. These low gas volume fraction streams can be found at well heads in mature fields as noted in Table 1, the liquid legs of inefficient or under-sized separators (7), and in heavy oil fields (8). …”
Section: Multiphase Metering Techniquesmentioning
confidence: 99%
“…This multiphase meter can measure oil, water and gas in production streams with gas volume fraction of less than 25%. These low gas volume fraction streams can be found at well heads in mature fields as noted in Table 1, the liquid legs of inefficient or under-sized separators (7), and in heavy oil fields (8). …”
Section: Multiphase Metering Techniquesmentioning
confidence: 99%
“…For the majority of wells, accuracies of ±1% FS ± 3% R were obtained. Field testing, New Mexico [Mehdizadeh et al 2009]: More than five low-GVF (< 30%) wells underwent qualification testing, indexed against a three-phase separator with single-phase meters on the outlet. Liquid rates of the MPFM were found to be within ±7% of reference measurements, while water-cut values were within ±1%.…”
Section: Mpfm-50 -300 and -400 Seriesmentioning
confidence: 99%
“…First, the precision of the MPFM shown in catalogues was reviewed [17][18][19][20][21][22][23] . The precision of the liquid rate, water cut, gas rate, and temperature presented by most important MPFM manufacturers are shown on table 6.…”
Section: Fig 17 Typical Z Type Behaviormentioning
confidence: 99%