2002
DOI: 10.1016/s0886-3350(02)01439-6
|View full text |Cite
|
Sign up to set email alerts
|

Phakic refractive lens experience in Spain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
37
0
3

Year Published

2005
2005
2017
2017

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 62 publications
(43 citation statements)
references
References 27 publications
3
37
0
3
Order By: Relevance
“…This indicates that these highly myopic patients improved their final visual acuity (postoperate BSCVA) although its mean is 0.7 (logMAR equivalent) with better BSCVA. These results are comparable to or better than those obtained in other isolated pIOL series [12][13][14][15][16][17][18][19] and to those of cataract surgery with IOL implantation in high myopia. 20 The most appropriate pIOL should be determined by its visual results and complications in prospective comparative studies and not only by isolated series reports.…”
Section: Discussionsupporting
confidence: 84%
“…This indicates that these highly myopic patients improved their final visual acuity (postoperate BSCVA) although its mean is 0.7 (logMAR equivalent) with better BSCVA. These results are comparable to or better than those obtained in other isolated pIOL series [12][13][14][15][16][17][18][19] and to those of cataract surgery with IOL implantation in high myopia. 20 The most appropriate pIOL should be determined by its visual results and complications in prospective comparative studies and not only by isolated series reports.…”
Section: Discussionsupporting
confidence: 84%
“…42,48 In addition, any condition associated to a potential zonular weakening should be also considered as a contraindication for the implantation of PRL, such as history of ocular trauma with secondary zonular damage, Marfań s syndrome diagnosis, or other systemic illnesses characterized by fragility of the cilliary processes. 37 A preoperative evaluation of the zonule by means of ultrasound technology is recommended in order to confirm structural integrity.…”
Section: Preoperative Assessment and Patient Selection For Prl Implanmentioning
confidence: 99%
“…26,[29][30][31][32]38,42 Hoyos et al 42 . After surgery, mean SE in the myopic group was À 0.31 ± 0.51 D and À 0.60 ± 0.63 D in the hyperopic group.…”
Section: Refractive Outcomesmentioning
confidence: 99%
“…11,26 In our cases, contact between the PIOL and the anterior capsule was responsible for an asymptomatic subcapsular anterior opacity, whose time of presentation does not support surgical trauma as cause. The IOL used in the present series is commercialized both for phakic and aphakic eyes and has a reduced haptic angulation compared with the new hyperopic Morcher PIOL (Z-SAL 4 Plus), which was not available at the time of the study.…”
Section: Discussionmentioning
confidence: 57%
“…[5][6][7][8][9][10][11] Refractive lens exchange is, however, irreversible and causes loss of accommodation.…”
Section: Q 2005 Ascrs and Escrsmentioning
confidence: 99%