2004
DOI: 10.1016/j.otohns.2004.05.027
|View full text |Cite
|
Sign up to set email alerts
|

Phase 1 Clinical Trial Results of the Envoy System: A Totally Implantable Middle Ear Device for Sensorineural Hearing Loss

Abstract: B-2.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
97
0
3

Year Published

2007
2007
2020
2020

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 79 publications
(100 citation statements)
references
References 9 publications
(12 reference statements)
0
97
0
3
Order By: Relevance
“…Modern ossicular reconstruction techniques may effectively restore hearing to within 10 dB. Speech discrimination was markedly improved over hearingaid by 17% as per the Phase One trial of Envoy Implantable System from St. Croix Medical Inc. 4 Functional gain and speech reception thresholds were similar for the Envoy device and for the hearing aids. The technology platform of the TIHD is different from all other microphone-based hearing devices (hearing aids, other middle ear implants or cochlear implants).…”
Section: Discussionmentioning
confidence: 93%
“…Modern ossicular reconstruction techniques may effectively restore hearing to within 10 dB. Speech discrimination was markedly improved over hearingaid by 17% as per the Phase One trial of Envoy Implantable System from St. Croix Medical Inc. 4 Functional gain and speech reception thresholds were similar for the Envoy device and for the hearing aids. The technology platform of the TIHD is different from all other microphone-based hearing devices (hearing aids, other middle ear implants or cochlear implants).…”
Section: Discussionmentioning
confidence: 93%
“…Modern ossicular reconstruction techniques may effectively restore hearing to within 10 dB. Speech discrimination was markedly improved over hearing-aid by 17% as per the Phase One trial of Envoy Implantable System from St. Croix Medical Inc [4]. Functional gain and speech reception thresholds were similar for the Envoy device and for the hearing aids.…”
Section: Discussionmentioning
confidence: 95%
“…Outro modelo de IOM totalmente implantável é o Esteem  (Envoy), no qual a captação do sinal acústico dá-se por um sensor piezoelétrico conectado diretamente à bigorna, e a estimulação é feita por um atuador também piezoelétrico ligado ao estribo. Neste caso, o papel do microfone é desempenhado pelo conjunto formado pela membrana timpânica e o transdutor piezoelétrico, o que proporciona um sinal acústico de maior qualidade devido às propriedades naturais da orelha externa e média (Barbara et al, 2009;Chen et al, 2004). No caso do Esteem, o sistema é alimentado por baterias cuja reposição deve ser feita a cada 5 a 9 anos, dependendo do modelo e variando de um paciente para outro, através de cirurgia ambulatorial (Green, 2011).…”
Section: Implantes De Orelha Médiaunclassified