2000
DOI: 10.1002/(sici)1522-2594(200003)43:3<470::aid-mrm20>3.0.co;2-u
|View full text |Cite
|
Sign up to set email alerts
|

Phase ordering with automatic window selection (PAWS): A novel motion-resistant technique for 3D coronary imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
66
0

Year Published

2001
2001
2011
2011

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 76 publications
(66 citation statements)
references
References 13 publications
0
66
0
Order By: Relevance
“…This could be done for example by increasing the acquisition windows within the cardiac and/or respiratory cycles (taking advantage of the motion insensitivity of radial imaging, and possibly combined with motion correction [38]), by parallel imaging (perhaps in conjunction with new 32-channel receiver systems) or by reducing the intershot repetition time to one heartbeat. As with all free-breathing coronary studies, the scan-time can be prolonged when the subject's breathing pattern drifts, and our methods would therefore benefit greatly from techniques such as PAWS [39] or 3D-MAG [40], which can mitigate this problem to some extent.…”
Section: Discussionmentioning
confidence: 99%
“…This could be done for example by increasing the acquisition windows within the cardiac and/or respiratory cycles (taking advantage of the motion insensitivity of radial imaging, and possibly combined with motion correction [38]), by parallel imaging (perhaps in conjunction with new 32-channel receiver systems) or by reducing the intershot repetition time to one heartbeat. As with all free-breathing coronary studies, the scan-time can be prolonged when the subject's breathing pattern drifts, and our methods would therefore benefit greatly from techniques such as PAWS [39] or 3D-MAG [40], which can mitigate this problem to some extent.…”
Section: Discussionmentioning
confidence: 99%
“…Phase ordering with automatic window selection 11 was implemented to maximize the respiratory efficiency. For the left main stem, left anterior descending (LAD), and left circumflex coronary arteries, a 3-dimensional volume was imaged by use of a 3-point plan-scan tool with the center of the volume focused on the left main coronary artery.…”
Section: Cardiovascular Magnetic Resonancementioning
confidence: 99%
“…3D motion adapted gating 3D-MAG is a 3D extension of the multi-level approach PAWS (phase-ordering with automatic window selection) and does not require predefined gating windows [26]. The navigator information is used in real-time to decide prospectively which part of the 3D-k-space should be acquired next.…”
Section: Standard Navigatormentioning
confidence: 99%