2017
DOI: 10.1049/joe.2017.0480
|View full text |Cite
|
Sign up to set email alerts
|

Phasor model simulation of a grid integrated variable speed pumped storage system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
1
1

Relationship

3
3

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…The switching dynamics can also be ignored because the PWM frequency in the threelevel VSC NPC is much larger than the system frequency [23]. Therefore, the model of VSC NPC was developed based on (16). where u dqr ,u dqg and m dqr ,m dqg are converter-injected voltages and modulated signals respectively in the rotor and grid-side converters.…”
Section: The Vsc-npc Converter Modeling For Deploying Vspsmentioning
confidence: 99%
See 1 more Smart Citation
“…The switching dynamics can also be ignored because the PWM frequency in the threelevel VSC NPC is much larger than the system frequency [23]. Therefore, the model of VSC NPC was developed based on (16). where u dqr ,u dqg and m dqr ,m dqg are converter-injected voltages and modulated signals respectively in the rotor and grid-side converters.…”
Section: The Vsc-npc Converter Modeling For Deploying Vspsmentioning
confidence: 99%
“…Therefore, grid frequency control is performed through an active power control strategy, which is an open-loop control scheme for frequency, as shown in Figure 1. Therefore, the response of grid frequency and AC voltage lacks good dynamic performance, especially during emergencies [16].…”
Section: Introductionmentioning
confidence: 99%
“…It has been presented and validated that the operating characteristics qualify the performances and dynamic responses of the developed control system when contingencies and faults occur in an electric power system in electromagnetism transient programs [1–11, 14, 17, 20–28, 33, 36, 38–41]. On the other hand, phasor model simulation is quite important to study electromechanical transient behaviours in large‐scale power systems as the VSPS grid‐integrated system are large likewise in which the simulation time is critical, the computing is vital and the difficulty of small insight quantities for control and protection designs occurs [10, 42–44]. Hence, phasor model simulation is reasonably significant for such solutions.…”
Section: Modelling and Control Strategies Employed In Difm Vsps Systemmentioning
confidence: 99%
“…Hence, phasor model simulation is reasonably significant for such solutions. Nevertheless, frequency‐invariant phasor model simulation is explicitly studied only in [44] and its effectiveness is validated for the dynamic responses in the VSPS grid‐integrated system.…”
Section: Modelling and Control Strategies Employed In Difm Vsps Systemmentioning
confidence: 99%
“…e active power is controlled by adjusting the rotor speed especially during the pumping mode [19][20][21]. A doubly fed induction machinebased variable-speed pumped storage (VSPS) system was established to investigate the performances in generating mode based on a comparison of phasor model and detailed model simulations [22]. e reactive/active power responses in a very short time for voltage and frequency control enables more dynamic tracking of the load variation because the power of the pump-turbine is proportional to the third power of the unit speed [21,23,24].…”
Section: Introductionmentioning
confidence: 99%